EasyManua.ls Logo

Toshiba e-STUDIO350 - Page 94

Toshiba e-STUDIO350
764 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
e-STUDIO350/352/353/450/452/453 © 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 74
593 Image Gamma data
slope adjust-
ment
Text/Photo PPC 0
<0-99>
SYS One’s place:
0:Equivalent to the set
value 5
1 to 9: Select the slope
of Gamma curve
(The larger the
value is, the larger
the slope
becomes.)
Ten’s place:
0: Equivalent to the set
value 5
1 to 9: Select the slope
of low density (The
smaller the value is,
the darker the back-
ground becomes.)
00: Use default value
1
594 Image Photo PPC 0
<0-99>
SYS 1
595 Image Text PPC 0
<0-99>
SYS 1
596-0 Image Gamma bal-
ance adjust-
ment
(PS/Photo)
Low
density
PRT 128
<0-255>
SYS When the value
increases, the density
in the target area
becomes higher.
4
596-1 Image Medium
density
PRT 128
<0-255>
SYS 4
596-2 Image High
density
PRT 128
<0-255>
SYS 4
597-0 Image Gamma bal-
ance adjust-
ment
(PS/Text)
Low
density
PRT 128
<0-255>
SYS When the value
increases, the density
in the target area
becomes higher.
4
597-1 Image Medium
density
PRT 128
<0-255>
SYS 4
597-2 Image High
density
PRT 128
<0-255>
SYS 4
598-0 Image Gamma bal-
ance adjust-
ment
(PCL/Photo)
Low
density
PRT 128
<0-255>
SYS When the value
increases, the density
in the target area
becomes higher.
4
598-1 Image Medium
density
PRT 128
<0-255>
SYS 4
598-2 Image High
density
PRT 128
<0-255>
SYS 4
599-0 Image Adjustment of
gamma bal-
ance
(PCL/Detail)
Low
density
PRT 128
<0-255>
SYS When the value
increases, the density
in the target area
becomes higher.
4
599-1 Image Medium
density
PRT 128
<0-255>
SYS 4
599-2 Image High
density
PRT 128
<0-255>
SYS 4
620 Image Sharpness
adjustment
Text/Photo PPC 1
<0-99>
SYS When the value
increases, the image
becomes sharper.
When the value
decreases, the image
becomes softer. The
smaller the value is, the
less the moire
becomes.One’s place:
Fixed value (05-620 is
“1”, 05-621 is “2”, 05-
622 is “5”) Ten’s place:
Sharpness intensity (0:
Use default value, 1-9:
Filter intensity)
1
621 Photo PPC 2
<0-99>
SYS 1
622 Text PPC EUR: 45
UC: 45
JPN: 45
<0-99>
SYS 1
Adjustment mode (05) <e-STUDIO352/353/452/453>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM Contents
Pro-
cedur
e
07/11

Table of Contents

Other manuals for Toshiba e-STUDIO350