ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 146
Procedure 14
Notes:
1. The digit after the hyphen in “Code” of the following table is a sub code.
2. e-STUDIO352/353/452/453:
In "RAM", the NVRAM of the board in which the data of each code is stored is indicated.
"M" stands for the LGC board, "SYS", "NIC" and "UTY" stands for the SYS board.
Setting mode (08) <e-STUDIO352/353/452/453>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM Contents
Pro-
cedur
e
200 General Date and time setting ALL -
<13 dig-
its>
- Year/month/date/day/
hour/minute/second
Example:
03 07 0 13 13 27 48
“Day” - “0” is for “Sun-
day”. Proceeds Monday
through Saturday from
“1” to “6”.
5
201 General Destination selection ALL EUR: 0
UC: 1
JPN: 2
<0-2>
M0: EUR
1: UC
2: JPN
1
202 User
interface
Counter installed externally ALL 0
<0-3>
M 0: No external counter
1: Coin controller
2: Copy key card
(This value is valid
only when “2” is set
to 08-201.)
3: Key copy counter
1
203 General Line adjustment mode ALL 0
<0-1>
M 0: For factory ship-
ment
1: For line
* Field: “0” must be
selected
1
204 User
interface
Auto-clear timer setting ALL 3
<0-10>
SYS Timer to return the
equipment to the
default settings when
the [START] button is
not pressed after the
function and the mode
are set
0: Not cleared
1 to 10:
Set number x 15
sec.
1
[0][8]
[POWER]
[POWER]
OFF/ON
(Exit)
[Digital key]
(Code)
[Digital key]
(Sub-code)
[CLEAR]
(Corrects value)
[START] [START]
[CANCEL]
[ENTER]
or
[INTERRUPT]
Adjustment value
cannot be changed
07/11