142 H7 ASD Operation Manual
Accel/Decel Pattern #4
Program
Special Control Parameters
Accel/Decel #1 – #4
Settings
This parameter enables a user-selected preprogrammed output profile that
controls the acceleration and deceleration pattern for the #4 Accel/Decel
parameter.
Settings:
Linear
S-Pattern 1
S-Pattern 2
Direct Access Number F516
Parameter TypeSelection List
Factory DefaultLinear
Changeable During Run — Yes
Accel/Decel Switching Frequency #3
Program
Special Control Parameters
Accel/Decel Special
This parameter sets the frequency at which the acceleration control is switched
from the Accel #3 profile to the Accel #4 profile during a multiple-acceleration
profile configuration.
Direct Access Number F517
Parameter TypeNumerical
Factory Default0.00
Changeable During Run — Yes
Minimum — 0.00
Maximum — Max. Freq. (F011)
Units — Hz
F516 F517