–84–
7. HYDRO UNIT INSTALLATION MANUAL
Engineering Data Book
7
Electrical supply/cable specifications
Wiring specifications
Wiring specifications (control line)
Control parts specifications
Output line specifications
Description POWER SUPPLY
Maximum
current
Installation fuse
rating
Power wire
Connection
destination
Outdoor unit
power
14 kW 230 V ~ 50 Hz 22.8 A 25 A 2.5 mm² or more
, 11 kW 230 V ~ 50 Hz 22.8 A 25 A 2.5 mm² or more
8 kW 230 V ~ 50 Hz 20.8 A 25 A 2.5 mm² or more
Outdoor-Hydro 1.5 mm² or more , ,
Hydro inlet heater
power
3 kW 230 V ~ 50 Hz 13 A 16 A 1.5 mm² or more , (TB02)
6 kW 400 V 3N ~ 50 Hz 13 A (13 A x 2P) 16 A 1.5 mm² or more
, , ,
(TB02)
9 kW 400 V 3N ~ 50 Hz 13 A (13 A x 3P) 16 A 1.5 mm² or more
Hydro cylinder heater power 230 V ~ 50 Hz 12 A 16 A 1.5 mm² or more , (TB03)
Hydro - cylinder 12 A 1.5 mm² or more , (TB03)
Description Line spec
Maximum
current
Maximum length
Connection
destination
3-way valve control 2 line or 3 line 100 mA 12 m 0.75 mor more
, ,
(TB05)
Mixing valve control 3 line 100 mA 12 m 0.75 mor more
, ,
or
, ,
(TB04)
2-zone thermo sensor 2 line 100 mA 5 m 0.75 mm² or more , (TB06)
Cylinder thermo sensor
2+GND(shield
wire)
100 mA 5 m 0.75 mm² or more , (TB06)
Second remote controller 2 line 50 mA 50 m 0.75 mm² or more , (TB07)
Power Maximum current Type
Motorized 3-way valve
(for hot water)
AC 230 V 100 mA
Spring return type
Note: 3-wire SPST and SPDT type can be used by changing
DIP switch 13-1.
Motorized 2-way valve
(for cooling)
AC 230 V 100 mA spring return type (normally open)
Motorized mixing valve
type 1 (for 2-zone)
AC 230 V 100 mA
60 sec 90º. SPDT type
Note: SPST and 20 to 240 sec type can be used by changing
the function code.
Description Output
Maximum
current
Max
voltage
Maximum
length
External pump No.1 AC230V 1 A 12 m
External boost heater AC230V 1 A 12 m
Output as required when outdoor air
temperature is -20°C or less
Boiler control
Non-voltage
contacts
0.5 A AC230 V 12 m
Output as required when outdoor air
temperature is -10°C or less
1 A DC24 V 12 m
ALARM Output
Non-voltage
contacts
0.5 A AC230 V 12 m
1 A DC24 V 12 m
Compressor operation
output
Non-voltage
contacts
0.5 A AC230 V 12 m
1 A DC24 V 12 m
22-EN