–94–
7. HYDRO UNIT INSTALLATION MANUAL
Engineering Data Book
7
 Setting Function Codes for Hydro Unit and Remote Controller
Set function codes for various operation modes with the remote controller.
There are two types of setting.
1) Hydro Unit function code setting
2) Remote controller function code setting
Setting remote controller mode
<Setting Hydro Unit Function Code>
1 Press the TEST + SET + SELECT
buttons for four seconds or more
to enter the remote controller function code
setting mode.
2 Set the function code (CODE No.) with the
TEMP. buttons. (CODE No.: 01 to 91)
3 Set data (DATA) with the TIME buttons.
4 Press the SET button to determine the settings.
5 The CL button is enabled only before the SET button is pressed and the function code is
changed.
6 Press the TEST button to end the settings.
<Setting Remote Controller Function Code>
1 Press the TEST + CL + TEMP.
buttons for four seconds or more to enter the
remote controller function code setting mode.
2 Set the function code (CODE No.) with the
TEMP. buttons. (CODE No.: 01 to 13)
3 Set data (DATA) with the TIME buttons.
4 Press the SET button to determine the settings.
5 The CL button is enabled only before the SET button is pressed and the function code is
changed.
6 Press the TEST button to end the settings.