(9) Setting Frequency of Output to Internal Heater (function code 33 to 34)
The increase/decrease time is used to set the response time.
(10)Setting Night Setback (function code 26. remote controller function code 0F to 11)
Set the function when the NIGHT button on the remote controller is pressed.
Set enabling/disabling of this function, reduction temperature, start time, and end time.
If disabling is set, the night setback operation is not performed even when the NIGHT button is
pressed.
(11)Setting 2-Way Valve (for Cooling) Operation (function code 3C)
When using both cooling and heating operations and there is an indoor unit only for heating (such as floor
heating), install the 2-way valve and set this function code.
(12)Setting 3-Way Valve Operation (function code 54)
This setting is not necessary for normal installation. Make this setting to invert the logic circuit in case ports
A and B of the 3-way valve are wrongly attached and it cannot be rectified on site.
(13)Mixing valve types and setting
Set the time period from full close to full open of the 2-zone control mixing valve. Set a value that is 1/10 of
the actual time.
(14)Setting Heating/Hot Water Switching when Boiler Is Used (function code 3E)
When boiler is used, make this setting to operate the Hydro Unit by the instruction from the boiler.
(15)Setting Heat Pump Operating Time for Hot Water Supply Operation
Set the time period from the start of heat pump run to the start of heater energization at the beginning of hot
water supply operation. If a long period is set, it takes long time for heating water.
(16)Setting Cooling ON/OFF
Set this function when performing cooling operation.
(17)Remote controller time indication
24-hour or 12-hour notation is selected for the timer.
(18)Setting Nighttime Quiet Operation
Issue an instruction for low-noise mode operation to the outdoor unit. Enabling/disabling of this function, start
time, and end time can be set.
(19)Setting Alarm Tone
The remote controller alarm tone can be set.