Outdoor Unit
Installation Manual
– 4 –
• Do not modify this unit by removing any of the safety guards
orbyby-passinganyofthesafetyinterlockswitches.
•Afterunpackingtheunit,examineitcarefullyifthereare
possibledamage.
• Do not install in a place that might increase the vibration of the
unit.
•Toavoidpersonalinjury(withsharpedges),becarefulwhen
handlingparts.
•PerforminstallationworkproperlyaccordingtotheInstallation
Manual.
Inappropriate installation may result in water leakage, electric shock
or fire.
• When the Air to Water Heat Pump Hydro Unit is installed in a
smallroom,provideappropriatemeasurestoensurethatthe
concentration of refrigerant leakage occur in the room does
notexceedthecriticallevel.
•Tightentheflarenutwithatorquewrenchinthespecified
manner.Excessivetighteningoftheflarenutmaycausea
crackintheflarenutafteralongperiod,whichmayresultin
refrigerantleakage.
•Wearheavyglovesduringtheinstallationworktoavoidinjury.
•InstalltheAirtoWaterHeatPumpsecurelyinalocationwhere
thebasecansustaintheweightadequately.
•Performthespecifiedinstallationworktoguardagainstan
earthquake.
If the Air to Water Heat Pump is not installed appropriately,
accidents may occur due to the falling unit.
•Ifrefrigerantgashasleakedduringtheinstallationwork,
ventilatetheroomimmediately.
If the leaked refrigerant gas comes in contact with fire, noxious gas
may generate.
•Aftertheinstallationwork,confirmthatrefrigerantgasdoes
notleak.
If refrigerant gas leaks into the room and flows near a fire source,
such as a cooking range, noxious gas might generate.
•Electricalworkmustbeperformedbyaqualifiedelectricianin
accordancewiththeInstallationManual.
MakesuretheAirtoWaterHeatPumpusesadedicatedpower
supply.
An insufficient power supply capacity or inappropriate installation
may cause fire.
•Usethespecifiedwiresforwiringconnecttheterminals
securelyfix.
Topreventexternalforcesappliedtotheterminalsfrom
affectingtheterminals.
•WhentheAirtoWaterHeatPumpcannotcoolorheatwaterwell,
contactthedealerfromwhomyoupurchasedtheAirtoWater
HeatPumpasrefrigerantleakageisconsideredasthecause.
Inthecaseofrepairthatrequiresrefillofrefrigerant,ask
servicepersonnelaboutdetailsoftherepair.
The refrigerant used in the Air to Water Heat Pump is harmless.
Generally, the refrigerant does not leak. However, if the refrigerant
leaks in a room and a heater or stove burner in the room catches
fire, it may generate toxic gas.
When you ask service personnel for repairing refrigerant leakage,
confirm that the leakage portion has been completely repaired.
•Conformtotheregulationsofthelocalelectriccompanywhen
wiringthepowersupply.
Inappropriate grounding may cause electric shock.
• Do not install the Air to Water Heat Pump in a location subject
toariskofexposuretoacombustiblegas.
If a combustible gas leaks, and stays around the unit, a fire may occur.
•Installtherefrigerantpipesecurelyduringtheinstallationwork
beforeoperatingtheAirtoWaterHeatPump.
If the compressor is operated with the valve open and without the
refrigerant pipe, the compressor sucks air and the refrigeration cycle
is overpressurized, which may cause a burst or injury.
•Fortherefrigerantrecoverywork(collectionofrefrigerant
fromthepipetothecompressor),stopthecompressorbefore
disconnectingtherefrigerantpipe.
If the refrigerant pipe is disconnected while the compressor is working
with the valve open, the compressor sucks air and the refrigeration
cycle is overpressurized, which may cause a burst or injury.
• Do not use means to accelerate the defrosting process or to
clean,otherthanthoserecommendedbythemanufacturer.
•Theapplianceshallbestoredinaroomwithoutcontinuously
operatingignitionsources(forexample:openflames,an
operatinggasapplianceoranoperatingelectricheater).
•Donotpierceorburn.
•Beawarethatrefrigerantsmaynotcontainanodour.
•Theinstallationofpipe-workshallbekepttoaminimum.