8-6-2. Outdoor unit
No. Component name Check procedure
1
Compressor
Type
DX150A1T-21F
(401HW-E, 601HW-E)
NX220A1FJ-20N
(801HW-E, 1101HW-E)
Measure the resistance value of each winding with a tester.
2
Outdoor fan motor
Type
ICF-140-A43-1
(401HW-E, 601HW-E)
ICF-280-A60-1
(801HW-E, 1101HW-E)
Measure the resistance value of each winding with a tester.
3
4-way valve coil
Type
DXQ-1233
Measure the resistance value.
9 ± 0.9
Red
White
Black
401HW-E, 601HW-E
Location
Resistance
value
Red
White 1.04 - 1.16
White
Black 1.04 - 1.16
Black
Red 1.04 - 1.16 At 20°C
801HW-E, 1101HW-E
Location
Resistance
value
Red
White 1.16 - 1.28
White
Black 1.16 - 1.28
Black
Red 1.16 - 1.28 At 20°C
Red
White
Black
401HW-E, 601HW-E
801HW-E, 1101HW-E
Location Resistance value
Red
White
21.00 ± 1.05 White
Black
Black
Red
Location Resistance value
Red
White
32.6 ± 3.3 White
Black
Black
Red