33
5-2. Outdoor unit
HWT-401HW-E, HWT-601HW-E
HWT-801HW-E, HWT-1101HW-E
No. Component name Type name Rating
1
Compressor DX150A1T-21F
2
Outdoor fan motor ICF-140-A43-1 Output 43 W
3
Reactor CH-102 18 mH, 16 A
4
4-way valve coil DXQ-1233 DC12 V
5
Pulse motor valve (PMV) coil PQ-M10012-000313 DC12 V
6
Compressor case thermostat US-622KXTMQO-SS OFF = 125 ± 4°C, ON = 90 ± 5°C
7
PC board MCC-1768
8
High pressure switch ACB-4UB154W OFF = 4.15 + 0, -0.15 MPa
No. Component name Type name Rating
1
Compressor NX220A1FJ-20N
2
Outdoor fan motor ICF-280-A60-1 Output 60 W
3
Reactor CH-101 10 mH, 20 A
4
4-way valve coil DXQ-1233 DC12 V
5
Pulse motor valve (PMV) coil UKV-A040 DC12 V
6
PC board (Compressor) MCC-1705
7
PC board (Control) MCC-1675
8
High pressure sensor NSK-BH042J-873 0 - 4.15 MPa
9
High pressure switch ACB-4UB231W OFF = 4.60 +0, - 0.3 MPa
10
Compressor case thermostat US-622 OFF = 125 ± 4°C, ON = 90 ± 5°C
11
2-way valve coil INJ TEV-SMOAG2260A1 AC220 - 240 V
12
Check valve INJ BCV-302DY
13
Pulse motor valve (PMV) coil INJ FAM-MD12TF-1