EasyManua.ls Logo

Toshiba HWT-601XWHM3W-ETR - 3-2.Refrigeration Cycle System Diagram

Toshiba HWT-601XWHM3W-ETR
230 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
3-2. Refrigeration cycle system diagram
HWT-601XWHM3W-E, HWT-601XWHT6W-E
HWT-401HW-E, HWT-601HW-E
HWT-1101XWHM3W-E, HWT-1101XWHT6W-E, HWT-1101XWHT9W-E
HWT-801HW-E, HWT-1101HW-E
Outdoor unit
TS
TO
Flow sensor
Plate-type
water heat
exchanger
Air vent
valve
Expansion vessel
High-pressure switch
TE
Low
pressure
sensor
Overpressure
preventive
valve
TW O
Backup
heater
TW I
Circulation
pump
THO
4-way valve
TC
Hydro unit
Outdoor heat exchanger
Heating / Hot water supply
Defrosting / Cooling
TL
Manometer
P
PMV
TD
Compressor
Outdoor unit
TS
TD
Accumulator
High pressure
sensor (PD)
High-pressure switch
4-way valve
Heating / Hot water supply
Defrosting / Cooling
Flow sensor
Plate-type
water heat
exchanger
Air vent
valve
Expansion vessel
Low
pressure
sensor
Overpressure
preventive
valve
TW O
Backup
heater
TW I
Circulation
pump
THO
TC
Hydro unit
Manometer
P
TO
TE
Outdoor heat exchanger
TL
Compressor
PMV1
PMV2
Check
valve
2-way valve

Table of Contents