149
Remote controller DN table
* 14~1A: for floor drying function
DN Item Details Fist shipment
02 Temperature correction by the room temperature sensor
(heating)
-10K~+10K: By 1K steps -1: -1K correction
03 Temperature correction by the room temperature sensor
(cooling)
-10K~+10K: By 1K steps -1: -1K correction
09 Night time low-noise mode 0: Invalid 1: Valid 0: Invalid
0A Night time low-noise start time 0 - 23 (0:00 to 23:00) 22: 22:00
0B Night time low-noise end time 0 - 23 (0:00 to 23:00) 06: 06:00
0C Anti bacteria start time 0 - 23 (0:00 to 23:00) 22: 22:00
0D Anti bacteria start cycle 1 - 10 (Every day to 10-day cycle) 07: 7-day cycle
0E Starting time of Night setback 0 - 23 (0:00 to 23:00) 22: 22:00
0F Ending time of Night setback 0 - 23 (0:00 to 23:00) 06: 06:00
11 Remote controller Alarm Tone. 0: Alarm Tone OFF 1: Alarm Tone ON 1: Alarm Tone ON
12 Frost running period (days) (0 days – 20 days) 00: No setting
13 Frost running period (hours) (0 hours – 23 hours) 00: No setting
14 Start and End temperature 20 - 55 (20°C - 55°C) 00: No setting
15 Max temperature 20 - 55 (20°C - 55°C) 00: No setting
16 Continuation days for every step up to Max temperature 1 - 7 (1 day - 7 days) 00: No setting
17 Temperature difference for every step up to Max
temperature
1 - 10 (1 K - 10 K) 00: No setting
18 Continuation days for every step down to End
temperature
1 - 7 (1 day - 7 days) 00: No setting
19 Temperature difference for every step down to End
temperature
1 - 10 (1 K - 10 K) 00: No setting
1A Continuation days in Max temperature 1 - 50 (1 day - 50 days) 00: No setting
1B Power consumption function is using 0000: No 0001: Yes 0001: Yes
1C Language setting 0000: English
0002: French
0004: Spanish
0006: Dutch
0008: Czech
0010: Croatian
0012: Portuguese
0014: Danish
0001: Turkish
0003: German
0005: Italian
0007: Finnish
0009: Hungarian
0011: Slovenian
0013: Polish
0015: Swedish
0000: English
1D Floor drying setting 0000: OFF 0001: ON 0000: OFF
1E Temperature sensor using in room temperature control 0000: OFF 0001: ON 0000: OFF

Table of Contents