– 43 –
* This compressor is driven with a 6-pole motor. The value of the compressor frequency (rps) measured with a
clamp meter at the compressor lead line is three times the rotation count (rps) of the compressor.
* Each compressor may have a different frequency as a measure against resonance.
* The temperature of the indoor heat exchanger (TC) indicates TCJ sensor temperature when cooling, and
TWO (TC2) sensor temperature when heating, respectively.
And the temperature of the Hot Water Module indicates TWO (TC2) sensor temperature when heating only.
<SMMS-u>
Outdoor
Unit
MMY-MUP()
HT8
Operating
Mode
Pressure
(MPa)
Pipe Surface Temperature
(ºC)
Compressor Rotation
(rps)
Indoor Heat
Exchanger
Pd
3.0
2.4
3.1
2.8
3.4
2.5
3.7
2.4
3.2
2.5
3.4
2.5
3.3
2.5
3.5
2.7
3.7
2.6
Ps
1.0
0.7
1.0
0.7
1.1
0.7
1.1
0.7
1.0
0.6
1.0
0.6
0.9
0.6
1.0
0.6
1.0
0.6
TD1
79
67
82
79
86
75
91
73
85
71
90
72
92
79
94
82
98
81
TS1
21
2
21
2
21
1
20
1
19
-1
19
-2
20
0
27
-1
21
-1
TC2
15
25
15
23
15
25
16
26
15
27
14
27
14
25
15
25
15
24
TE1
39
1
40
0
40
0
41
-1
43
1
42
2
43
0
42
0
43
0
TL3
26
21
26
17
29
16
33
22
28
17
28
22
31
1
29
-4
30
20
Cmp. 1
50
57
56
63
65
75
77
83
65
68
70
77
77
82
71
79
78
79
Cmp. 2
70
77
77
77
TO
35
7
35
7
35
7
35
7
35
7
35
7
35
7
35
7
35
7
TA
27
20
27
20
27
20
28
20
27
20
27
20
27
20
27
20
27
20
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
0801
1001
1201
1401
1601
1801
2001
2201
2401
Discharge Suction
Outdoor Heat
Exchanger
Liquid
Temperature
Compressor 1 Compressor 2
Outdoor Indoo
Indoor
Fan
Air Temperature
(DB/WB)(ºC)
<SHRM-e>
Compressor
1
Compressor
2
2.9
2.6
3.1
2.6
3.2
2.6
3.2
2.6
3.2
2.8
3.1
2.8
3.1
2.8
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
0.9
0.7
0.9
0.7
0.9
0.7
0.9
0.7
0.9
0.7
0.9
0.7
0.9
0.6
80
75
85
80
90
85
90
80
90
85
80
70
85
75
16
5
16
4
16
3
16
4
16
3
15
4
15
3
10
35
11
35
11
35
10
35
10
30
11
30
11
30
40
3
40
2
40
2
40
3
40
2
40
3
40
2
30
30
30
30
30
25
35
30
35
25
35
25
35
25
50
50
60
65
70
75
60
65
70
70
70
75
80
85
50
50
60
65
70
75
60
65
70
70
70
75
80
85
High
High
High
High
High
High
High
High
High
High
High
High
High
High
27/19
20/-
27/19
20/-
27/19
20/-
27/19
20/-
27/19
20/-
27/19
20/-
27/19
20/-
35/-
7/6
35/-
7/6
35/-
7/6
35/-
7/6
35/-
7/6
35/-
7/6
35/-
7/6
Indoor
fan
Outdoor
Outdoor
unit
MMY-
MAP
Operating
mode
Pressure
(MPa)
PsPd
Air temperature
condition (°C)
Number of compressor
rotations (rps)
Pipe surface temperature
(°C)
Liquid
temperatre
(TL3)
Indoor
0806*
Outdoor
heat
exchanger
(TE)
Indoor heat
exchanger
(TC)
Suction
(TS)
Discharge
(TD)
1006*
1206*
1406*
1606*
1806*
2006*
* This compressor is driven with a 4-pole motor. The value of the compressor number of rotations (rps)
measured with a clamp meter at the compressor lead line is two times the rotation count (rps) of the
compressor.
* Each compressor may have a different frequency as a measure against resonance.
* The temperature of the indoor heat exchanger (TC) indicates TCJ sensor temperature when cooling, and
TC2 sensor temperature when heating, respectively.