WHEN REPLACING EEPROM (MEMORY) IC
If a service repair is undertaken where it has been required to change the MEMORY IC, the following steps should be taken to
ensure correct data settings while making reference to TABLE 1.
NOTE: No need setting for after INI 2F due to the adjustment value.
Table 1
1.
2.
Enter DATA SET mode by setting VOLUME to minimum.
While holding down VOLUME button on front cabinet, press key 6 on remote control.
ADDRESS and DATA should appear as FIG 1.
Fig. 1
3.
4.
5.
6.
7.
8.
9.
10.
11.
The unit will now have the correct DATA for the new MEMORY IC.
ADDRESS is now selected and should "blink". Using the SET +/- button on the remote, step through the ADDRESS until
required ADDRESS to be changed is reached.
Press ENTER to select DATA. When DATA is selected, it will "blink".
Again, step through the DATA using SET +/- button until required DATA value has been selected.
Pressing ENTER will take you back to ADDRESS for further selection if necessary.
Repeat steps 3 to 6 until all data has been checked.
When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.
After the data input, set to the initializing of shipping.
Turn POWER on.
While holding down VOLUME button on front cabinet, press key 1 on remote control.
After the finishing of the initializing of shipping, the unit will turn off automatically.
C4-1
08 0A 70 6B C2 B3 24 A9 51 2E
+0 +1 +2 +3 +4 +5 +6 +7 +8 +9
+A
+B +C +D +E +FINI
B2 92 93 00 1A 31 05 08 80
00 3A 10 25 54 60 23 3B DA D7
00 06 00 40 00 1000
10
9A
A9 0F 94 43 06 14
20 00 00 00 00 00 00
INIT 00 08
POWER ON 0010
PLAY/REC 0003
ADDRESS DATA