4.25 LCD unit/FL inverter 4 Replacement Procedures
4.25 LCD unit/FL inverter
Removing the LCD unit/FL inverter
The following describes the procedure for removing the LCD unit/FL inverter. (See Figure 4-
43 to 4-46.)
NOTE: When replacing the LCD unit, do not give the hinge portion a strong press. It may
cause the breakage of the hinge assembly.
Also, Use a stand or something under the LCD part to keep the LCD part level
while replacing it.
1. Turn the display 180 degree and close the display. (LCD turns to the front.)
2. Peel off the mask seals (7 points) from the LCD mask and remove the following
screws securing the LCD mask.
• M2.5×6.0B FLAT HEAD screw ×6
• M2.0×6.0S BIND screw ×1
3. Insert your fingers into the slot on both sides and remove the LCD mask while
releasing latches.
M2.5x6.0B FLAT HEAD
with mask seal
M2.0x6.0S BIND
with mask seal
M2.5x6.0B FLAT HEAD
with mask seal
Slot
LCD mask
Figure 4-43 Removing the LCD mask
PORTEGE M400 Maintenance Manual (960-541) [CONFIDENTIAL] 4-63