Power supply input Wiring Diagram
PowersupplyinputatIndoorunitTerminalBlock(Recommend)
Power supply
input
L
N
GND
NL 1 2 3
Indoor
Terminal
Block
Outdoor
Terminal
Block
INDOOR UNIT
OUTDOOR UNIT
CHASSIS
CHASSIS
EARTH
1 2 3
PowersupplyinputatOutdoorunitTerminalBlock(Optional)
Power supply
input
GND
L
N
INDOOR UNIT
OUTDOOR UNIT
CHASSIS
Indoor
Terminal
Block
Outdoor
Terminal
Block
CHASSIS
EARTH
NL 1 2 3
1 2 3 L N
1.Thepowersupplymustbesameastheratedofairconditioner.
2.Preparethepowersourceforexclusiveusewithairconditioner.
3.Circuitbreakermustbeusedforthepowersupplylineofthisairconditioner.
4.Besuretocomplypowersupplyandconnectingcableforsizeandwiringmethod.
5.Everywiremustbeconnectedfirmly.
6.Performwiringworkssoastoallowageneralwiringcapacity.
7.Wrongwiringconnectionmaycausesomeelectricalpartburnout.
8.Incorrectorincompletewiringiscarriedout,itwillcauseanignitionorsmoke.
9.Thisproductcanbeconnectedtomainpowersupply.
Connectiontofixedwiring:Aswitchwhichdisconnectsallpolesandhasacontactseparationatleast3mmmustbeincorporatedinthefixedwiring.
13