How to remove the drain hose
Drain hose
•Thedrainhosecanberemovedbyremovingthe
screwsecuringthedrainhoseandthenpullingout
thedrainhose.
•Whenremovingthedrainhose,becarefulofany
sharpedgesofsteelplate.Theedgescaninjuries.
•Toinstallthedrainhose,insertthedrainhose
firmlyuntiltheconnectionpartcontactswithheat
insulator,andthensecureitwithoriginalscrew.
How to remove the drain cap
Clipthedraincapbyneedle-nose
pliersandpullout.
How to x the drain cap
1)Inserthexagonwrench(4mm)
in a centerhead.
2)Firmlyinsertthedraincap.
Do not apply lubricating oil
(refrigerant machine oil)
when inserting the drain
cap. Application causes
deterioration and drain
leakage of the plug.
No gap
Insert a hexagon wrench
(4 mm).
Firmlyinsertthedrainhoseanddraincap;otherwise,watermayleak.
In case of right or left piping
Slit
•Afterscribingslitsofthebackbody
withaknifeoramaking-opin,cut
themwithapairofnippersoran
equivalenttool.
In case of bottom right or bottom left piping
Slit
•Afterscribingslitsofthebackbody
withaknifeoramaking-opin,cut
themwithapairofnippersoran
equivalenttool.
Left-hand connection with piping
•Bendtheconnectingpipesothatitislaidwithin43mmabovethewall
surface.Iftheconnectingpipeislaidexceeding43mmabovethewall
surface,theindoorunitmayunstablybesetonthewall.
Whenbendingtheconnectingpipe,makesuretouseaspringbenderso
asnottocrushthepipe.
Bend the connecting pipe within a radius of 30 mm.
Toconnectthepipeafterinstallationoftheunit(figure)
(To the forefront of flare)
Gas side
Liquid side
260 mm
210 mm
43 mm
80°
Outward form of indoor unit
R 30 mm (Use polisin (polyethylene)
core or the like for bending pipe.)
Use the handle of screwdriver, etc.
Ifthepipeisbentincorrectly,theindoorunitmayunstablybesetonthewall.
Afterpassingtheconnectingpipethroughthepipehole,connectthe
connectingpipestotheauxiliarypipesandwrapthefacingtapearound
them.
•Bindtheauxiliarypipes(two)andconnectingcablewithfacingtape
tightly.Incaseofleftwardpipingandrear-leftwardpiping,bindthe
auxiliarypipes(two)onlywithfacingtape.
Indoor unit
Connecting cable
Auxiliary pipes
Installation plate
•Carefullyarrangepipessothatanypipedoesnotstickoutoftherear
plateoftheindoorunit.
•Carefullyconnecttheauxiliarypipesandconnectingpipestoone
anotherandcutotheinsulatingtapewoundontheconnectingpipeto
avoiddouble-tapingatthejoint;moreover,sealthejointwiththevinyl
tape,etc.
•Sincedewingresultsinamachinetrouble,makesuretoinsulateboth
connectingpipes.(Usepolyethylenefoamasinsulatingmaterial.)
•Whenbendingapipe,carefullydoit,nottocrushit.
Indoor Unit Fixing
1.Passthepipethroughtheholeinthewallandhooktheindoorunitonthe
installationplateattheupperhook.
2.Swingtheindoorunittorightandlefttoconfirmthatitisfirmlyhookedup
ontheinstallationplate.
3.Whilepressingtheindoorunitontothewall,hookitatthelowerparton
theinstallationplate.Pulltheindoorunittowardyoutoconfirmthatitis
firmlyhookedupontheinstallationplate.
Hook here.
Installation plate
Hook
Press
(unhook)
Push
Push
•Fordetachingtheindoorunitfrom
theinstallationplate,pulltheindoor
unittowardyouwhilepushingits
bottomupatthespecifiedparts.
Drainage
1.Runthedrainhoseslopeddownwards.
•Theholeshouldbemadeataslightdownwardslantontheoutdoorside.
Do not rise the
drain hose.
Do not from the
drain hose into
a wavy shape.
50 mm
or more
Do not put the
drain hose end
into water.
Do not put the
drain hose end
in the drainage ditch.
7
1122950109_S04_182x257_52p_S_p70_181217_EN+TR+RU.indd 9 12/25/2018 10:46:53 AM