EasyManua.ls Logo

Toshiba RAS-10SAVP-ND - Control Block Diagram

Toshiba RAS-10SAVP-ND
119 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
More user manuals on ManualsBase.com
25
8. CONTROL BLOCK DIAGRAM
8-1. Indoor Unit
RAS-B10SKVP-E, RAS-B13SKVP-E, RAS-B16SKVP-E
/
RAS-10SKVP-ND, RAS-13SKVP-ND, RAS-16SKVP-ND
M.C.U.
Indoor Unit Control Unit
From Outdoor Unit
220-240V
~
50Hz
220V
~
60Hz (-E model only)
Serial Signal Communication
(Operation Command and Information)
Serial Signal Transmitter/Receiver
Micro Switch
Converter
(D.C circuit)
Noise Filter
Indoor
Fan Motor
Air purifier
unit
Louver
Motor
Louver Motor
Drive Control
Indoor Fan
Motor Control
Initializing Circuit
Clock Frequency
Oscillator Circuit
Power Supply
Circuit
Infrared Rays, 36.7kHz
Remote Controller
8˚C (-ND model only)
Operation Mode Selection
AUTO, COOL, DRY, HEAT
REMOTE CONTROLLER
OFF (1, 3, 5, 9H OFF timer)
Air Purifier
Hi POWER
SLEEP MODE
Louver Direction Setting
Louver AUTO Swing
OFF TIMER Setting
ON TIMER Setting
Fan Speed Selection
Thermo. Setting
Operation (START/STOP)
Heat Exchanger Sensor (Tc)
Heat Exchanger Sensor (Tcj)
Room Temperature Sensor (Ta)
Infrared Rays Signal Receiver
and Indication
Functions
Cold draft preventing Function
3-minute Delay at Restart for
Compressor
Fan Motor Starting Control
Processing
(Temperature Processing)
Timer
Serial Signal Communication
Clean Function

Other manuals for Toshiba RAS-10SAVP-ND