EasyManua.ls Logo

Toshiba RAS-10SAVP-ND - Set Temp. Correction

Toshiba RAS-10SAVP-ND
119 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
More user manuals on ManualsBase.com
– 45 –
Jumper wire
J801
J802
J803
J804
Item
18. Set temp.
correction
Operation flow and applicable data, etc.
<Indoor control P.C. board (At shipment)>
<In HEAT operation>
At shipment
¡: With Jumper wire
×
: Cut Jumper wire
<In 8°C HEAT operation> (–ND model only)
At shipment
¡: With Jumper wire
×
: Cut Jumper wire
Description
1. Purpose
When the difference between the set
temp. of the remote controller and the
room temp. is wide due to the installation
condition, etc, the set temp. is corrected.
(HEAT operation only)
2. Description
The set temp. received from the remote
controller is corrected. The correct value
from –2°C to +4°C is changed by the
jumper wire on P.C. board of the indoor
microcomputer.
Jumper wire setup
J801 J802
××
×
¡
¡
×
¡¡
HEAT
shift value
–2
+4
+2
0
Jumper wire setup
J803 J804
××
×
¡
¡
×
¡¡
HEAT
shift value
–2
+4
+2
0

Other manuals for Toshiba RAS-10SAVP-ND

Related product manuals