– 36 –
FILE NO. SVM-04022
7-8-2. How to cancel auto restart function
To cancel auto restart function, proceed as follows:
Repeat the setting prodedure: the unit receives the
signal and beeps three times.
The unit will be required to be turned on with the
remote control after the main power supply is turned
off.
When the unit is on standby (Not operating)
When the unit is in operation
While this function is being set, if the unit is in
operation, the orange lamp is on.
7-8-3. Power failure during timer operation
When the unit is in Timer operation, if it is turned off
because of power failure, the timer operation is
cancelled. Therefore, set the timer operation again.
7-9.Filter Check Lamp
When the operation time of Plasma Air-Purifier
reaches 500 hours, the filter check lamp indicates.
After cleaning the Plasma Air-Purifier, turn off the filter
check lamp.
7-9-1. How to turn off filter check lamp
Press [FILTER] button on the remote control.
OR push [RESET] button on the indoor unit.
Note :
If [RESET] button is pushed while the filter check lamp
is not indicating, the indoor unit will start the Automatic
Operation.
Operation Motions
Push [RESET] button for more The unit is on standby.
than three seconds.
The unit starts to operate. The orange lamp is on.
After approx. three seconds,
The unit beeps three times The lamp changes from
and continues to operate. orange to green.
If the unit is not required to operate at this time, push [
RESET
] button
once more or use the remote control to turn it off.
Operation Motions
Push [RESET] button for more The unit is in operation. The orange lamp is on.
than three seconds.
The unit stops operating. The orange lamp is turned off.
After approx. three seconds,
The unit beeps three times.
If the unit is required to operate at this time,
push [
RESET
] button
once more or use the remote control to turn it on.
0
3S
RESET Hi POWER FILTER PAP TIMER
0
3S
RESET Hi POWER FILTER PAP TIMER

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba RAS-13UAH-E3 and is the answer not in the manual?

Toshiba RAS-13UAH-E3 Specifications

General IconGeneral
Cooling Capacity3.5 kW
Heating Capacity4.0 kW
Energy Efficiency Ratio (EER)3.21
Coefficient of Performance (COP)3.61
RefrigerantR410A
Power Supply220-240V, 50Hz
Weight (Indoor Unit)9 kg
Noise Level (Outdoor)50 dB
TypeSplit