– 3 –
FILE NO. SVM-04022
MODEL RAS-13NKHD-E/ RAS-13UAH-E 3 RAS-13NKD-E / RAS-13UA-E3
ITEM Cooling Heating Cooling
Capacity
220 V 240 V 220 V 240 V 220 V 240 V
kW 3.55 3.60 4.40 4.45 3.70 3.75
Phase 1∅
Power source V 220 − 240
Hz 50
Power consumption kW 1.27 1.32 1.26 1.33 1.24 1.28
Power factor % 98 96 98 96 98 95
Running Indoor A 0.15
current Outdoor A 5.75 5.60 5.70 5.65 5.75 5.60
Starting current A 25 24
Moisture removal lit/h 2.0
Noise
Indoor (H/M/L) dB 41/35/31
Outdoor (220 − 240 V) dB 49 51 49 51 47 48
Refrigerant
Name of refrigerant R22
Rated amount kg 1.00 0.80
Refrigerant control Capillary tube
Gas side size mm ∅12.7
Connection type Flare connection
Liquid side size mm ∅6.35
Interconnection
Connection type Flare connection
pipe
Maximum length
1
(One way)
Maximum height
difference
INDOOR UNIT RAS-13NKHD-E RAS-13NKD-E
Height mm 275
Dimensions Width mm 790
Depth mm 218
Net weight kg 10
Evaporator type Finned tube
Indoor fan type Cross flow fan
High fan m
3
/h 630 650 630
Air volume Medium fan m
3
/h 520 550 520
Low fan m
3
/h 430 490 430
Fan motor output W 20
Air filter Honeycomb woven filter with PP frame
OUTDOOR UNIT RAS-13UAH-E3 RAS-13UA-E3
Height mm 550
Dimensions Width mm 780
Depth mm 270
Net weight kg 37 34
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume m
3
/h 2120
2200
2120 2200 2030 2150
Fan motor output W
42
Compressor
Model PH170T2-4L2 PH225X2C-4FT
Output W 1100
Safety device Fuse, Overload relay
Louver type Automatic louver
Usable outdoor temperature range °C 15 ~ 43 −10 ~ 24 15 ~ 43
1. SPECIFICATIONS
m
m
6
30
15*