FILE NO. SVM-04022
40 –
8-2. Installation Diagram of Indoor and Outdoor Units
13 series 07, 10 series
A 600 mm 400 mm
B 100 mm 45 mm
600 mm or more
B mm
or more
1
00 m
m
o
r m
ore
A
m
m
o
r
m
o
re
60
0
m
m
o
r m
ore
Vinyl tape
Apply after
carrying out a
drainage test.
Extension
drain hose
(Option:
RB–821SW)
Insulate the refrigerant
pipes separately with
insulation, not together.
For the rear left and left
piping
Insert the cushion between
the indoor unit and wall,
and tilt the indoor unit for
better operation.
Wall
6 mm thick heat resisting
polyethylene foam
Saddle
Do not allow the drain hose
to get slack.
Make sure to run the drain
hose sloped downward.
Cut the piping hole
sloped slightly
Before installing the
wireless remote control
With the remote control cover
open, load the batteries supplied
correctly, observing their
polarity.
Shield
pipe
A
ir
f
ilt
er
Ho
ok
Hook
(A
tta
c
h
to
th
e
fr
o
n
t p
a
n
e
l.)
65 mm or more
170 m
m
or m
ore
1 Installation
plate
2 Wireless remote control
170 mm or more
4 Zeolite-plus
filter
6 Plasma air purifier
3 Batteries
2 Wireless remote control
Cover
The auxiliary piping can be
connected the left, rear left,
rear right, right, bottom right
or bottom left.
Right
Rear right
Bottom right
Left
Rear left
Bottom left