9-6-2. How to shorten time of restart delay timer
1 Press [SET] button while pressing [CHECK] button
with a tip of a pencil.
2 Then press [
] button to transmit the signal to the
indoor unit.
Table 9-6-2. Approximate resistance value of thermo sensor
Temperature 0°C10°C20°C25°C30°C
Resistance value 33.8 20.35 12.59 10.00 7.99
(kΩ)
9-6-3. How to set/cancel self cleaning function
The self cleaning function is set from a factory. To cancel this function, should keep press the RESET switch on
Indoor unit for 20 seconds till can hear the long combination sound and repeat the same procedure when need
to set.