FILE NO. SVM-06021
4. SPECIFICATION OF ELECTRICAL PARTS
4-1. Indoor Unit (RAS-24GFHP-ES2, RAS-18GFHP-ES2)
4-2. Outdoor Unit (RAS-24GAH-ES2)
No. Parts name Type Specifications
Output (Rated) 2200W, 2poles, 1 phase, 220 240V, 50Hz
1 Compressor PA290X3CS-4MU1 Winding resistance () Red-Black White-Black
(at 20°C) 1.13 2.10
Output (Rated) 42W, 4poles, 1 phase, 220 – 240V, 50Hz
2 Fan motor (for outdoor) FG-240-42A-1 Winding resistance () Red-Black White-Black
(at 20°C) 128 126
3
Running capacitor
451305L AC 450V, 3.0µF
(for fan motor)
4
Running capacitor
RS44B506U0218S AC 440V, 50µF
(for compressor)
5
Solenoid coil
VHV (STF) AC 220 ~ 240V
(for 4-way valve)
6 Thermo sensor TE / TD 10k at 25°C / 50k at 25°C
7 Magnetic contactor CLK-35J 220 ~ 240V, 50Hz
8 Transformer TT-05 220 ~ 240V
9 Microcontroller TMP47C840N
10 Varistor (R73, R74) 15G471K 470V
11 Fuse (F01) TSCR T6.3A, 250V
- 12 -
No. Parts name Type Specifications
1 Fan motor (for indoor) AFP-220-50-4A Output (Rated) 50W, 220-240V
2 Thermo sensor (TA-sensor) ——— 10k at 25°C
3 DC-DC transformer (T01) SWT-47 DC 390V, Secondary DC 12V, 7V
4 Microcomputer TMP87CM40AN
5
Heat exchanger sensor
——— 10k at 25°C
(TC-sensor)
6 Line filter (L01) SS11V-R07190 19mH, AC0.7A
7 Diode (DB01) D3SBA60 4A, 600V
8 Capacitor (C02) EKMH401VSN470MP20S 47µF, 400V
9 Fuse (F01) TSCR T6.3A, 250V
10 Varistor (R21, R22) 15G561K 560V
11 Resistor (R01) RF-2TK5R6 5.6, 2W
12 Louver motor MP35EA12
Output (Rated) 2W, 6poles, 4phase,
DC 12V

Table of Contents