FILE NO. SVM-06021
16
5-2. RAS-18GFP-ES2 / RAS-18GA-ES2
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Standard 1.1 10.0 High 27/19 35/24
Cooling High temperature 1.2 13.0 High 32/23 43/26
Low temperature 0.6 2.0 Low 21/15 21/15
50Hz
Fan speed
(indoor)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Standard
pressure P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe T (°C)
Indoor unit
Multi blade fan
Compressor
Condenser
Propeller fan
Outdoor unit
PA225X2CS-4KU1
O.D.:6.35 mm
Packed valve
(12.70)
Packed valve
T
P
Refrigerant
R-410A 1.26 Kg
Evaporator
0.49m
(Connecting pipe)
6.35 mm
Mark ( ) means check points of Gas Leak
O.D.:12.70 mm
0.39m
(Connecting pipe)
12.70 mm
12.70 mm
0.39m
(Flexible pipe)
(∅6.35)
Capillary tube
1.7x400
S

Table of Contents