FILE NO. SVM-06021
18
5-4. RAS-24GFP-ES2 / RAS-24GA-ES2
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Standard 3.183 7.0 High 27/19 35/24
Cooling High temperature 4.040 11.7 High 32/23 43/26
Low temperature 1.651 -0.4 Low 21/15 21/15
50Hz
Fan speed
(indoor)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Standard
pressure P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe T (°C)
Evaporator
Indoor unit
Multi blade fan
Compressor
Condenser
Tank
Propeller fan
Outdoor unit
Capillary tube
2.0x900S
PA290X3CS-4MU1
Cooling
O.D.:6.35 mm
Packed valve
(12.70 )
Packed valve
(∅6.35)
0.49m
(Connecting pipe)
6.35 mm
T
P
Refrigerant
R-410A 1.70 Kg
Mark ( ) means check points of Gas Leak
O.D.:12.70 mm
Cooling
0.39m
(Connecting pipe)
12.70 mm
12.70 mm
0.39m
(Flexible pipe)

Table of Contents