FILE NO. SVM-06021
1) Perform the common procedure 1
2) Remove the capacitor band. (1 screw ∅4 x 10L)
3) Disconnect the lead wires from the capacitor
terminal.
1) Perform the common procedure 1
2) Remove the fixing screw. (1 screw ∅4 x 10L)
3) Disconnect the lead wires from the capacitor
terminal.
1) Perform the common procedure 1
2) Remove the fixing screw. (2 screws ∅4 x 16L)
3) Disconnect the lead wires from the terminal.
1) Perform the common procedure 1
2) Remove the fixing screw. (1 screws ∅4 x 10L)
3) Disconnect the lead wires from the terminal.
2 Running
capacitor
for compressor
3 Running
capacitor
for fan motor
4 Magnetic
contactor
5 Spark killer
(Cooling only model)
Spark killer
Running capacitor
for compressor
Running capacitor
for fan motor
Magnetic contactor
Cooling only model
Procedures
Remarks
Part name
No.
- 74 -