14
Power Supply Input at Outdoor Unit Terminal Block (Recommend)
Indoor Unit Outdoor Unit
Connecting cable
connect to 1 2 3
Terminal block (L N 1 2 3)
Earth line
Connecting
cable
Connecting cable
Stripping length of the
connecting cable
3
2
1
Earth line
50 mm
10 mm
70 mm
10 mm
12
3
LN
50 mm
60 mm
40 mm
45 mm
10 mm
10 mm
10 mm
10 mm
Earth line Earth line
Connecting cable Power supply cable
Power Supply Input at Indoor Unit Terminal Block (Optional)
Indoor Unit Outdoor Unit
Power supply cable
connect to L N
Terminal block (L N 1 2 3)
Earth line
Power supply
cable
Power supply cable
Stripping length of the power
supply cable
N
L
Earth line
50 mm
10 mm
70 mm
10 mm
12
3
60 mm
45 mm
10 mm
10 mm
Earth line
Connecting cable
Connecting cable
connect to 1 2 3
Terminal block (L N 1 2 3)
Earth line
Power supply
cable
Connecting
cable
Earth line
Connecting cable
Stripping length of the
connecting cable
3
50 mm
Earth line
10 mm
70 mm
10 mm
In Case of Indoor Unit Connect With 1:1 Outdoor Unit