5. SPECIFICATIONS OF ELECTRICAL PARTS
5-1. Indoor Unit
RAS-M10UKV-E3, RAS-M13UKV-E3, RAS-M16UKV-E3
RAS-M10UKCV-E3, RAS-M13UKCV-E3, RAS-M16UKCV-E3
No. Parts name Type Specifications
1 Fan motor (for indoor) ICF-35-19-4 DC 340V, 30W
2 Thermo. sensor (TA-sensor) ( ) 10k at 25°C
3 DC-DC transformer (T01) SWT-70 DC 390V, Secondary DC 15V, 12V, 7V
4 Microcomputer ( – )
5
Heat exchanger sensor
( ) 10k at 25°C
(TC-sensor)
6 Line filter (L01) SS11V-06270 27mH, AC 0.64A
7 Diode (DB01) D3SBA60 4A, 600V
8 Capacitor (C03) KMH450VNSN120M25C 120µF, 450V
9 Fuse (F01) FCU250V3.15A T3.15A, 250V
10 Power supply IC (IC01) STR-L472
11 Varistor (R21, R109) 15G561K 560V
12 Resistor (R01) RF-5TK4R7 4.7, 5W
13 Louver motor MP24GA Output (Rated) 1W, 16 poles, 1 phase DC12V