– 49 –
7-2. Outdoor Unit (Inverter Assembly)
RAS-4M27YAV-E, RAS-4M27YACV-E, RAS-3M26YAV-E
A unit P.M.V.
A unit
send/receive
circuit
B unit
send/receive
circuit
C unit
send/receive
circuit
D unit
send/receive
circuit
*
1
*
2
*
1
*
2
Clock frequency
oscillator circuit
16MHz
Clock frequency
oscillator circuit
10MHz
Outdoor
fan
motor
• Inverter outdoor frequency control
• A/D converter function
• P.M.V. control
• Discharge temp. control
• Error display
• Signal communication to MCU
• PWM synthesis function
M.C.U
• PWM synthesis function
• Input current release control
• IGBT over current detect control
• High power factor correction control
• Signal communication to MCU
• Output current release control
• A/D converter function
M.C.U (DSP)
Discharge temp. SensorGas side pipe temp. Sensor Suction temp. Sensor Evaporator temp. SensorOutdoor air temp. Sensor
MCC-818 (SUB-P.C. B)
MCC-1359 (MAIN-P.C. B)
220–240V, 50/60Hz
Driver
circuit of
P.M.V.
Signal communication
to MCU
Inverter
(DC
AC)
Over current
sensor
Compressor
B unit P.M.V.
C unit P.M.V.
D unit P.M.V.
4-Way valve Relay circuit
Noise filter
Over current
sensor
Inverter
(DC
AC)
Output current
sensor
Input current
sensor
Converter
(AC
DC)
P.M.V : Pulse modulating valve
PWM : Pulse width modulation
IGBT : Insulated gate bipolar
transistor
DSP : Digital signal processor
Rotor position
detect circuit
Gate drive
circuit
Over current
detect circuit
High power factor
correction circuit
Over current
detect circuit
Gate drive
circuit
NOTE :
*
1 : 4 unit multi model only
*
2 : Heat pump model only