EasyManua.ls Logo

Toshiba RAS-M18GACV-E - Troubleshooting; Unit Inoperability Checks; Performance Issue Checks

Toshiba RAS-M18GACV-E
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 30 –
7-2. Operation Data
<Cooling> RAS-M14GAV-E, RAS-M14GACV-E
<Heating> RAS-M14GAV-E
NOTES :
1. Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor themometer)
2. Connecting piping condition : 7.5 m × 2 units
<Cooling> RAS-M18GAV-E, RAS-M18GACV-E
<Heating> RAS-M18GAV-E
Temperature
condition (°C)
Indoor Outdoor
27 / 19 35 / –
No.of
operating
units
1 unit
2 units
Operating combination
(Unit)
AB
10
13
10 10
13 10
Standard
pressure
P (MPa)
0.7 to 0.9
0.9 to 1.1
0.9 to 1.1
0.9 to 1.1
Heat exchanger
pipe temp.
T1 (°C) T2 (°C)
11 to 13 43 to 45
8 to 11 47 to 49
14 to 16 47 to 49
14 to 16 47 to 49
Indoor
fan
High
High
High
High
Outdoor
fan
700rpm
750rpm
750rpm
750rpm
Compressor
revolution
(rps)
39
66
64
65
Temperature
condition (°C)
Indoor Outdoor
20 / – 7 / 6
No.of
operating
units
1 unit
2 units
Operating combination
(Unit)
AB
10
13
10 10
13 10
Standard
pressure
P (MPa)
2.2 to 2.4
2.5 to 2.7
1.9 to 2.1
1.9 to 2.1
Heat exchanger
pipe temp.
T1 (°C) T2 (°C)
36 to 38 0 to 2
41 to 43 –1 to 1
30 to 32 –1 to 1
30 to 32 –1 to 1
Indoor
fan
High
High
High
High
Outdoor
fan
750rpm
750rpm
750rpm
750rpm
Compressor
revolution
(rps)
60
76
78
80
Temperature
condition (°C)
Indoor Outdoor
27 / 19 35 / –
No.of
operating
units
1 unit
2 units
Operating combination
(Unit)
AB
10
13
16
10 10
13 10
13 13
16 10
Standard
pressure
P (MPa)
0.9 to 1.1
0.8 to 1.0
0.8 to 1.0
0.9 to 1.1
0.9 to 1.1
0.9 to 1.1
0.9 to 1.1
Heat exchanger
pipe temp.
T1 (°C) T2 (°C)
11 to 13 41 to 43
8 to 10 45 to 47
7 to 09 47 to 49
11 to 13 48 to 50
11 to 13 48 to 50
11 to 13 48 to 50
11 to 13 48 to 50
Indoor
fan
High
High
High
High
High
High
High
Outdoor
fan
700rpm
750rpm
750rpm
750rpm
750rpm
750rpm
750rpm
Compressor
revolution
(rps)
35
58
75
71
71
71
71
Temperature
condition (°C)
Indoor Outdoor
20 / – 7 / 6
No.of
operating
units
1 unit
2 units
Operating combination
(Unit)
AB
10
13
16
10 10
13 10
13 13
16 10
Standard
pressure
P (MPa)
3.2 to 3.4
3.4 to 3.6
3.4 to 3.6
2.6 to 2.8
2.6 to 2.8
2.6 to 2.8
2.6 to 2.8
Heat exchanger
pipe temp.
T1 (°C) T2 (°C)
44 to 46 0 to 2
50 to 53 0 to 2
51 to 53 0 to 2
37 to 39 –1 to 1
38 to 40 –1 to 1
38 to 40 –1 to 1
38 to 40 –1 to 1
Indoor
fan
High
High
High
High
High
High
High
Outdoor
fan
750rpm
750rpm
750rpm
750rpm
750rpm
750rpm
750rpm
Compressor
revolution
(rps)
62
81
85
93
101
101
101

Table of Contents