– 6 –
•(∗) The RAS-B16GKVP-E cannot be used in combination with the RAS-M14GAV-E.
• For performance when each indoor unit is combined with other unit, refer to the separate table.
• The specifications may be subject to change without notice for purpose of improvement.
2-1. Specifications
<Heat Pump Models>
RAS-B10GKVP-E, RAS-B13GKVP-E, RAS-B16GKVP-E / RAS-M14GAV-E, RAS-M18GAV-E
Unit model
Indoor
Outdoor
Cooling capacity (kW)
Cooling capacity range (kW)
Heating capacity (kW)
Heating capacity range (kW)
Power supply
Unit model
Indoor
Running current (A)
(220V/230V/240V)
Power consumption (W)
Power factor (%)
Electric
Unit model
characteristics
Operation mode
Outdoor
Running current (A)
(220V/230V/240V)
Power consumption (W)
Power factor (%)
Starting current (A)
COP (Cooling/Heating)
Unit model
Indoor
High (dB•A)
Operating
(Cooling/Heating)
Medium (dB•A)
noise
Low (dB•A)
Outdoor
Unit model
(Cooling/Heating)
2 indoor units operating (dB•A)
Unit model
Height (mm)
Dimension Width (mm)
Indoor unit Depth (mm)
Net weight (kg)
Fan motor output (W)
Air flow rate (Cooling/Heating) (m³/h)
Unit model
Height (mm)
Dimension Width (mm)
Depth (mm)
Net weight (kg)
Outdoor unit Motor output (W)
Compressor Type
Model
Fan motor output (W)
Air flow rate (m³/h)
Type
Indoor unit
Unit model
Liquid side/Gas side
Outdoor unit
Unit model
Liquid side/Gas side
Piping
Maximum length (per unit) (m)
Maximum length (total) (m)
connection
Maximum chargeless length (total) (m)
Maximum height difference (m)
Additional refrigerant
Name of refrigerant
Weight (kg)
Wiring
Power supply
connection
Interconnection
Usable
Indoor (Cooling/Heating) (°C)
temperature range
Outdoor (Cooling/Heating) (°C)
Unit model
Installation plate
Wireless remote controller
Batteries
Remote controller holder
Indoor unit Zeolite-plus filter
Plasma pure filter
Accessory
Remote controller holder mounting screw
Owner’s manual
Mounting screw
Installation manual
Unit model
Installation manual
Outdoor unit Specifications
Drain nipple
Water-proof rubber cap
RAS-B10GKVP-E, RAS-B13GKVP-E, RAS-B16GKVP-E
RAS-M14GAV-E RAS-M18GAV-E
4.0 5.2
1.4 – 4.5 1.4 – 6.2
4.4 6.7
0.9 – 5.2 0.9 – 8.5
220–240 V – 1 Ph – 50Hz / 220 V – 1 Ph –60Hz
RAS-B10GKVP-E RAS-B13GKVP-E RAS-B16GKVP-E (*)
0.15 0.15 0.15
30 30 30
91/87/83 91/87/83 91/87/83
RAS-M14GAV-E RAS-M18GAV-E
Cooling Heating Cooling Heating
4.87/4.64/4.44 4.43/4.23/4.04 7.12/6.80/6.50 8.28/7.91/7.57
1020 950 1540 1790
95 97 98 98
5.17/4.94/4.74 7.42/7.10/6.80
3.70/4.36 3.25/3.62
RAS-B10GKVP-E RAS-B13GKVP-E RAS-B16GKVP-E (*)
42/43 43/44 45/45
33/34 34/35 36/36
27/27 27/27 29/29
RAS-M14GAV-E RAS-M18GAV-E
46/48 48/50
RAS-B10GKVP-E RAS-B13GKVP-E RAS-B16GKVP-E (*)
250 250 250
790 790 790
215 215 215
999
30 30 30
550/610 560/640 640/660
RAS-M14GAV-E RAS-M18GAV-E
550 550
780 780
290 290
36 40
750 1100
Twin rotary type with DC-inverter variable speed control
DA111A1F-20F1 DA130A1F-25F
43 43
1820 2100
Flare connection Flare connection
RAS-B10GKVP-E RAS-B13GKVP-E RAS-B16GKVP-E
Ø6.35/ Ø9.52 Ø6.35/ Ø9.52 Ø6.35/ Ø12.7
RAS-M14GAV-E RAS-M18GAV-E
Ø6.35/ Ø9.52 Ø6.35/ Ø9.52
20 20
30 30
20 20
10 10
20g/m (pipe length 21m to 30m) 20g/m (pipe length 21m to 30m)
R410A R410A
0.90 1.20
3 Wires : includes earth
4 Wires : includes earth
21 to 32/0 to 27
5 to 43/–10 to 24
RAS-B10GKVP-E RAS-B13GKVP-E RAS-B16GKVP-E
111
111
222
111
111
111
2 (Ø3.1 × 16L) 2 (Ø3.1 × 16L) 2 (Ø3.1 × 16L)
111
6 (Ø4 × 25L) 6 (Ø4 × 25L) 6 (Ø4 × 25L)
111
RAS-M14GAV-E RAS-M18GAV-E
11
11
11
22