– 21 –
No. Parts name Type Specifications
1 Fan motor (for indoor) TICF-35-19-4 DC35V, 19W
2 Thermo. sensor (TA-sensor) ( – ) 10k at 25°C
3 DC-DC transformer (T01) SWT-34 or SWT-46 DC390V, Secondary DC35V, 12V, 7V
4 Microcomputer
TMP87PM40AF or
TMP87CM40AF
5
Heat exchanger temp. sensor
( – ) 10k at 25°C
(TC-sensor)
6 Line filter (L01) UF-253Y0R7 25mH, AC0,7A
7 Diode (DB01) RBV-406 or D3SBA60 4A, 600V
8 Capacitor (C02) KMH450VNSN100M25B 100µF, 450V
9 Fuse (F01) TSCR6,3A T6,3A, 250V
10 Power supply IC (IC01) MA2830-FJ 4A, 600V
11 Varistor (R21, R109) 15G561K 560V
12 Resistor (R01) ERF-5TK5R6 5,6, 5W
13 Louver motor MP35EA7 Output (Rated) 2W, 10poles, 1phase DC12V
No. Parts name Model name Rating
1 SC coil (Noise filter)
L03 SC-15-S06J 15A, 0,6mH
L01 SC-20-01J 20A, 150µH
Primary side DC280V
2 DC-DC transformer SWT-43 Secondary side
7,5V x 1, 13V x 1, 26,5V x 3, 16V x 1, 15V x 1
3 Reactor CH38Z-K L=10mH, 16A x 2
4 Reactor CH43Z-K L=10mH, 1A
5 Outside fan motor ICF-140-40-7 DC140V, 40W
6 Fan control relay AJQ1341
Coil DC12V
Contact AC125V, 3A
7
Suction temp. sensor
(Inverter attached) 10k (25°C)
(TS sensor)
8
Discharge temp. sensor
(Inverter attached) 62k (20°C)
(TD sensor)
9
Outside air temp. sensor
(Inverter attached) 10k (25°C)
(TO sensor)
10
Temp. sensor at A room
(Inverter attached)
RAS-M18YACV-E ..........10k (25°C)
gas side (TGa sensor) RAS-M18YAV-E .............62k (20°C)
11 Terminal block (9P) ——— 20A, AC250V
12 Terminal block (3P) ——— 20A, AC250V
For protection of
3,15A, AC250V
switching power source
13 Fuse
For protection of transistor
15A, AC250V
module breakage
For protection of
25A, AC250V
inverter input overcurrent
14 Electrolytic capacitor
LLQ2G501KHUATF
500µF, DC400V X 4 pieces
400LISN500K35F
15 Transistor module 6MBI25GS-060-01 25A, 600V
16 Compressor DA130A1F-21F 3-phases 4-poles 1100W
17 Compressor thermo. PW-2AL OFF: 125 ± 4°C, ON: 90 ± 5°C
18 Converter module MP7002 Diode: 25A, 600V, IGBT: 40A, 600V
19
Heat exchanger temp. sensor
(Inverter attached) 10k at 25°C
(TE-sensor) (H/P only)
5-2. Outdoor Unit
RAS-M18YAV-E / RAS-M18YACV-E
5. SPECIFICATIONS OF ELECTRICAL PARTS
5-1. Indoor Unit
RAS-M10YKV-E, RAS-M13YKV-E / RAS-M10YKCV-E, RAS-M13YKCV-E