– 5 –
1-2. Specifications of Performance When Each Indoor Unit is Combined with Other Unit
<Cooling>
Operating Unit capacity Cooling Running Power Outdoor
indoor unit (kW) capacity current consumption
operating noise
ABAB kW A W dB
10 2,7 2,7 4,13 770 42
(1,1 to 3,2) (1,65 to 4,99) (255 to 930)
13 3,7 3,7 6,58 1240 46
(1,1 to 4,2) (1,65 to 7,25) (255 to 1430)
10 10 2,55 2,55 5,1 8,14 1700 46
(1,4 to 6,1) (1,68 to 10,29) (260 to 2150)
13 10 3,01 2,19 5,2 8,20 1720 46
(1,4 to 6,2) (1,68 to 10,38) (260 to 2170)
10 2,7 2,7 3,95 770 42
(1,1 to 3,2) (1,59 to 4,78) (255 to 930)
13 3,7 3,7 6,30 1240 46
(1,1 to 4,2) (1,59 to 6,94) (255 to 1430)
10 10 2,55 2,55 5,1 7,78 1700 46
(1,4 to 6,1) (1,62 to 9,84) (260 to 2150)
13 10 3,01 2,19 5,2 7,87 1720 46
(1,4 to 6.2) (1,62 to 9,93) (260 to 2170)
10 2,7 2,7 3,79 770 42
(1,1 to 3,2) (1,52 to 4,58) (255 to 930)
13 3,7 3,7 6,03 1240 46
(1,1 to 4,2) (1,52 to 6,65) (255 to 1430)
10 10 2,55 2,55 5,1 7,46 1700 46
(1,4 to 6,1) (1,55 to 9,43) (260 to 2150)
13 10 3,01 2,19 5,2 7,58 1720 46
(1,4 to 6,2) (1,55 to 9,52) (260 to 2170)
Volts
Operation
V
status
1 unit
220
2 units
1 unit
230
2 units
1 unit
240
2 units
<Heating>
The above specification values are those under the conditions
Cooling indoor : DB/WB=27/19°C Cooling outdoor : DB=35°C
Heating indoor : DB=20°C Heating outdoor : DB/WB=7/6°C
Operating Unit capacity Heating Running Power Outdoor
indoor unit (kW) capacity current consumption
operating noise
ABAB kW A W dB
10 4,0 4,0 6,94 1450 45
(0,7 to 5,2) (1,10 to 8,13) (170 to 1700)
13 5,0 5,0 9,86 2060 49
(0,7 to 6,5) (1,10 to 12,11) (170 to 2530)
10 10 3,2 3,2 6,4 8,47 1770 49
(0,9 to 8,3) (1,10 to 11,43) (170 to 2390)
13 10 3,72 2,98 6,7 8,85 1850 49
(0,9 to 8,7) (1,10 to 11,72) (170 to 2450)
10 4,0 4,0 6,64 1450 45
(0,7 to 5,2) (1,06 to 7,78) (170 to 1700)
13 5,0 5,0 9,43 2060 49
(0,7 to 6,5) (1,06 to 11,58) (170 to 2530)
10 10 3,2 3,2 6,4 8,10 1770 49
(0,9 to 8,3) (1,06 to 10,94) (170 to 2390)
13 10 3,72 2,98 6,7 8,47 1850 49
(0,9 to 8,7) (1,06 to 11,21) (170 to 2450)
10 4,0 4,0 6,36 1450 45
(0,7 to 5,2) (1,01 to 7,46) (170 to 1700)
13 5,0 5,0 9,04 2060 49
(0,7 to 6,5) (1,01 to 11,10) (170 to 2530)
10 10 3,2 3,2 6,4 7,76 1770 49
(0,9 to 8,3) (1,01 to 10,48) (170 to 2390)
13 10 3,72 2,98 6,7 8,11 1850 49
(0,9 to 8,7) (1,01 to 10,75) (170 to 2450)
Volts
Operation
V
status
1 unit
220
2 units
1 unit
230
2 units
1 unit
240
2 units