– 7 –
1-3. Electrical Data
<Cooling>
Combination
of indoor unit
operation
AB
10 —
13 —
10 10
13 10
System
Voltage range Power supply
Hz
Volts-
Min. Max. MCA ICF
MOCP
Ph.
(Amps)
5,81 5,81 15
50 230–1 198 264
8,51 8,51 15
12,10 12,10 15
12,21 12,21 15
Compressor Fan motor FLA
MSC RLA Indoor Outdoor
4,13 4,13 0,15 x 1=0,15 0,50
6,29 6,29 0,15 x 1=0,15 0,50
9,04 9,04 0,15 x 2=0,30 0,50
9,13 9,13 0,15 x 2=0,30 0,50
<Heating>
Combination
of indoor unit
operation
AB
10 —
13 —
10 10
13 10
System
Voltage range Power supply
Hz
Volts-
Min. Max. MCA ICF
MOCP
Ph.
(Amps)
9,56 9,56 15
50 230–1 198 264
14,31 14,31 15
13,47 13,47 15
13,81 13,81 15
Compressor Fan motor FLA
MSC RLA Indoor Outdoor
7,13 7,13 0,15 x 1=0,15 0,50
10,93 10,93 0,15 x 1=0,15 0,50
10,14 10,14 0,15 x 2=0,30 0,50
10,41 10,41 0,15 x 2=0,30 0,50
NOTE :
Model of Indoor unit :
10 : RAS-M10YKV-E, RAS-M10YKCV-E
13 : RAS-M13YKV-E, RAS-M13YKCV-E
MCA : Minimum Circuit Amps.
ICF : Maximum Instantaneous Current Flow
(Equivalent to MCA in case of inverter air conditioner)
MOCP : Maximum Overcurrent Protection (Fuse only)
MSC : Maximum Starting Current
FLA : Full Load Amps.
RLA : Rated Load Amps. RLA under conditions on the right.
<Cooling>
<Heating>
DB WB
Indoor temp. °C 20 —
Outdoor temp. °C 7 6
DB WB
Indoor temp. °C 27 19
Outdoor temp. °C 35 —