27
Item
(Only in heating
operation)
Operation flow and applicable data, etc. Description
connected outdoor unit.
8. ECO operation *Refer to SERVICE MANUAL of
9. Temporary
operation
7. Defrost control *Refer to SERVICE MANUAL of
connected outdoor unit.
Pushing [RESET] button starts the temporary
operation of [AUTO] operation. When keeping
[RESET] button pushed for 10 seconds or more, the
temporary [COOL] operation is performed.
1) When pushing [RESET] button, the
temporary [AUTO] operation starts.
2) When keeping [RESET] button pushed for
3 seconds or more, Pi, Pi, Pi sound is
heard and [AUTO RESTART] control is
changed.
3) When keeping [RESET] button pushed for
10 seconds or more, “Pi” sound is heard
and the temporary [COOL] operation
starts.
4) If the filter lamp goes on, push [RESET]
button to go off the filter lamp, and then
push [RESET] button again.
5) To stop the temporary operation, push the
button again.
Filter lamp ON
Push RESET button.
Did you push [RESET] button
for 3 seconds or more?
Did you push [RESET] button
for 10 seconds or more?
Switch to [AUTO RESTART] control.
YES
YES
NO
NO
NO
YES
Temporary [AUTO] operation
Temporary [COOL] Operation
FILE NO. SVM-12087

Table of Contents