11-6-3. Indoor Unit (Other Parts)
5
4
3
2
1
White
Yellow
Yellow
Yellow
Yellow
5
4
3
2
1
No.
1
2
3
4
Part name
Room temp. (TA) sensor
Heat exchanger (TC) sensor
Remote controller
Louver motor
MP24Z3T
Indoor fan motor
Checking procedure
Disconnect the connector and measure the resistance value with tester.
(Normal temp.)
Refer to 11-5-1. (5).
Measure the resistance value of each winding coil by using the tester.
(Under normal temp. 25°C)
Refer to 11-5-1. (3) and (4).
Temperature
Sensor
TA, TC (k)
10°C 20°C 25°C 30°C 40°C
20.7 12.6 10.0 7.9 4.5
Position
1 to 2
1 to 3
1 to 4
1 to 5
Resistance value
250 ± 20
– 85 –
11-7. How to Simply Judge Whether Outdoor Fan Motor is Good or Bad
Refer to SERVICE MANUAL of connected outdoor unit.
FILE NO. SVM-12087
66