Replacement Procedures
4.20 LCD unit / FL inverter
CAUTION: When replacing a LCD, it is required that SVP parameter is set. Update with
the latest EC/KBC as described in Appendix H “EC/KBC Rewrite
Procedures”.
Removing the LCD unit / FL inverter
The following describes the procedure for removing the LCD unit and FL inverter (See
Figure 4-31 to 4-34).
1. Remove Screw rubber cover X4
2. Remove the following screws securing the display mask
M2.5×4.0 BIND screw X4
3. Insert your finger between the edge of the display mask and the LCD, and remove the
display mask while releasing the latches of display mask.
M2.5x4.0
Figure 4-31 Removing the display mask
M 2.5X6.0 BIND screw
4-52Satellite U300 and Satellite Pro U300 Maintenance Manual (960-Q08)