8-6
INSTALLATION-WIRING DIAGRAMS
SECTION 100-816-208
MARCH 1993
1. Certron Corp; Anaheim, California 92807
Secondary protector: Model 08450.
2. Curtis Mfg. Co. Inc; Jaffrey, New Hampshire 03452
Secondary protector: Model Diamond Chip. For indoor use on the protected side of the
telephone circuit only.
3. Oneac Corp; Libertyville, Illinois 60048
Secondary protector: Model OnLine 614+ and OnLine DG/S. For indoor use on the
protected side of primary telephone protector only.
4. Siemon Co.; Watertown, Connecticut 06795
Secondary protector for communication circuits: Model PM-2305. Intended for use with
Listed Siemon 66M1 Block: Models PG-04, -25, -50, or PK-04 ground kit and Listed Type
1 enclosure. For use on the protected side of a Listed Primary Telecommunications
Protector for indoor use only.
5. Simplex Time Recorder Co.; Gardner, Massachusetts 01440
Isolated loop circuit protectors: Models 2081-9027 and 2081-9028. Intended for use
between data communication equipment or signal lines of building system equipment.
Install and test the secondary protectors per the installation instructions of the applicable
manufacturer.