REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES
SECTION 100-816-600
MARCH 1993
-24-
TABLE RM-M
PROGRAM 01
LOGICAL PORT DISPLAY
ACTIONSTEP DISPLAY/PRINTOUT
1
>MODE PROG
P
Enter the Program Mode
At the >MODE prompt, enter P R O G CR.
2 P 01
P01
Enter Program Number 01
Press CR.
3 P01
P01 01
Enter the Physical Port Number
4
5
Enter the desired physical port number.
Example: Port number 01, enter 0 1.
Verify Physical Port's Associated Logical Port
To Display More Ports/Exit Program
A) To display more logical ports, press CR and go to Step 3.
B) To exit this program, enter # # CR (twice).
P01 01 ##
P01 ##
P
(after exit)
Logical Port Displays
Physical Port
P01 01
( = Logical Port)
TABLE RM-N
PROGRAM 02
PHYSICAL PORT DISPLAY
ACTIONSTEP DISPLAY/PRINTOUT
1 >MODE PROG
P
Enter the Program Mode
At the >MODE prompt, enter P R O G CR.
2 P 02
P02
Enter Program Number 02
Press CR.
3 Enter the Logical Port Number
4
5
Enter the desired logical port number.
Example: Port number 02, enter 0 2.
Verify Logical Ports Associated Physical Port
To Display More Ports/Exit Program
A) To display more physical ports, press CR and go to Step 3.
B) To exit this program, enter # # CR (twice).
P02
P02 02
P02 02 ##
P02 ##
P
(after exit)
Physical Port Displays
Logical Port
P02 02
( = Physical Port)