Procedure 5 Battery Check
If the status indicator panel displays 100% charge for the battery and the time or percentage
displayed drops unexpectedly when you disconnect the AC adapter, the battery may not have
been used for a long time. If the remaining capacity display or available time to operate
decreases quickly after removing the AC adapter and the status indicator indicates 100%, the
following reasons may apply.
Battery was not used for long period of time.
Battery charging was started with the temperature difference between the
computer and the battery pack at more than 10°C. (A cold battery was
installed into an overheated PC.)
Then, perform the following checks:
Check 1 Fully discharge the battery by leaving the computer power on until it automatically
turns off.
Check 2 Connect the AC adapter and charge the battery. The battery charge may increase
quickly to 99%. Wait for the charge to reach 100%.
Check 3 Repeat checks 1 and 2 two or three times until the battery capacity recovers.