1. Remove two mask seals at the bottom corners of the
display assembly using a pair of fine-tipped tweezers.
2. Remove two M2.5x6 flat head brass screws securing
the display mask.
3. There are 23 latches securing the display mask.
Carefully insert your fingers between the mask and the
LCD panel and pry open the latches starting from the
bottom seven latches, to the five latches on the right
and left sides, ending with the six toplatches.
FL INVERTER AND 14.1” LCD REMOVAL
1. Lift the plastic shield.
2. Carefully lift up the FL inverter board and
disconnect the LCD/FL cable from CN1 and the
FL cable from CN2.
3. Remove four mask seals to expose four screws
securing the LCD module.
4. Remove four M2X4 brass screws securing the
LCD module.
5. Carefully rotate out the top of the LCD module
enough to access the display cable
6. Peel off the tape securing the LCD/FL cable and
disconnect the cable.
14.1” DISPLAY MASK REMOVAL
Latch
Mask seals
Display
mask
LCD
LCD/FL cable
LCD module
FL inverter board
M2x4
brass
screws
M2x4
brass
screws
Mask
seals
Mask
seals
FL cable
Plastic shield
TOSHIBA
Tough Enough for Today’s World.
FIELD REPLACEABLE UNIT DOCUMENTATION
Tecra
TM
8200 Series