E6582051
- 9 -
2.6.
LED indicator
The LED shows the present status of the network and module.
When PROFINET option is mounted to VF-AS3, please attach the LED label for PROFINET option to lower
side of communication indicator of VF-AS3.
The LED label is included in danger label kit of VF-AS3.
SF (Network status) and BF (Module status) are displayed on communication indicator.
The behavior of LNK LED
Link Activity
Color and behavior Meaning
OFF
No link
Green Blink Network Activity at 100 Mbps
Green ON
Link established at 100 Mbps
SF
LNK
BF
LNK

Table of Contents

Other manuals for Toshiba TOSVERT VF-AS3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-AS3 and is the answer not in the manual?

Toshiba TOSVERT VF-AS3 Specifications

General IconGeneral
ModelTOSVERT VF-AS3
CategoryInverter
Overload Capacity150% for 60 seconds
Cooling MethodForced Air Cooling
Control MethodV/f control, Sensorless vector control
Braking UnitBuilt-in
Communication ProtocolsModbus RTU, DeviceNet, Profibus DP
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Ground Fault
EnclosureIP20
Operating Temperature-10°C to +50°C
Humidity5-95% (non-condensing)
AltitudeUp to 1000m