E6582051
- 34 -
VF-AS3 profile
Scanner input
c001
-
c006
Scanner output
c021
-
c026
0: No action
1:
fa06
(Communication command 1)
2:
fa23
(Communication command 2)
3:
fa07
(Frequency command, 0.01Hz)
4:
fa33
(Torque command 0.01%)
5:
fa50
(Terminal output data)
6:
fa51
(Analog output(FM) data from comm.)
7: fa52 (Analog output(AM) data from comm.)
8:
f601
(Stall prevention level, %)
9:
f441
(Power running torque limit 1
level,0.01%)
10: f443 (Regenerative braking torque
limit 1 level, 0.01%)
11: f460 (Speed loop proportional gain)
12: f461 (Speed loop stabilization coefficient)
13:
acc
(Acceleration time 1, 0.1s) *
14:
dec
(Deceleration time 1, 0.1s) *
15:
ul
(Upper limit, 0.01Hz)
16:
vb
(Torque boost value 1, 0.01%)
17:
vlv
(Base frequency voltage 1, 0.1V)
0: No action
1:
fd01
(Status information 1)
2:
fd00
(Output frequency, 0.01Hz)
3:
fd03
(Output current, 0.01%)
4:
fd05
(Output voltage, 0.01%)
5:
fc91
(Inverter alarm)
6:
fd22
(PID feedback value, 0.01Hz)
7:
fd06
(Input terminal status)
8:
fd07
(Output terminal status)
9:
fe35
(RR input, 0.01%)
10:
fe36
(RX input, 0.01%)
11:
fe37
(II input, 0.01%)
12:
fd04
(Input voltage (DC detection), 0.01%)
13:
fd16
(Estimated speed (real-time value), 0.01Hz)
14:
fd18
(Torque, 0.01%)
15:fe60 (My monitor)
16:
fe61
(My monitor)
17:
fe62
(My monitor)
18:
fe63
(My monitor)
19:
f880
(Free notes)
20:
fd29
(Input power, 0.01kW)
21:
fd30
(Output power, 0.01kW)
22:
fe14
(Cumulative operation time, 1hour)
23:
fe40
(FM terminal output monitor, 0.01%)
24:
fe41
(AM terminal output monitor, 0.01%)
25:
fd20
(Torque current, 0.01%)
26:
fd23
(Motor overload factor, 0.01%)
27:
fd24
(Drive overload factor, 0.01%)
28:
fd25
(PBR overload factor, %)
29:
fd26
(Motor load factor, %)
30:
fd27
(Drive load factor, %)
31:
fe56
(Pulse train input, pps)
32:
fe70
(Drive rated current, 0.1A)
33:
fe76
(Input Watt-hour, 0.1kWh
10
f749
) **
34:
fe77
(Output Watt-hour, 0.1kWh
10
f749
) **
35:
fd83
(IGBT temperature, degree C)
* The unit of
acc
,
dec
is according to the parameter
f519
.
** The unit of
fe76
,
fe77
is according to the parameter
f749
.

Table of Contents

Other manuals for Toshiba TOSVERT VF-AS3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-AS3 and is the answer not in the manual?

Toshiba TOSVERT VF-AS3 Specifications

General IconGeneral
BrandToshiba
ModelTOSVERT VF-AS3
CategoryInverter
LanguageEnglish

Related product manuals