Page 89
Configuration Register 11 (Pulse / PWM Output): MW0011
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
P-OUT / PWM operation error flag
(These are not user setting items)
Bit D < PWM pulse width error >
0: Normal
1: Error
Bit E < PWM ON duty setting error >
0: Normal
1: Error
Bit F < Frequency setting error >
0: Normal
1: Error
Bit 0
< P-OUT and PWM master flag >
0: No use
1: Use
Bit 1 < P-OUT / PWM selection >
0: PWM
1: P-OUT
Bit 2 < PLS mode >
0: CW/CCW
1: Pulse/Direction (PLS/DIR)