END USER SETTINGS – SET POINT
DEFINITION DEPENDENCIES
FUNCTION
The “Set point Screen” is used to
adjust the current heat set point
and cool set point. The orange
Heat Set point Wheel is used to
adjust the heat set point. The blue
Cool Set point Wheel is used to
adjust the cool set point.
If the thermostat is setup as a Non-Programmable
thermostat then the Play Button / Pause Button
and associated text above and below these
buttons will not be present. If the thermostat is
setup in a Heat Only configuration then the Cool
Setpoint Wheel will be greyed and disabled. If the
thermostat is setup in a Heat Only configuration
then the Cool Setpoint Wheel will be greyed and
disabled.
An indoor equipment type must be
chosen so that an airflow source is
available to the system operation.
The two types of indoor equipment
defined for operation are a
FURNACE and an AIR HANDLER
(sometimes also referred to as a FAN
COIL). The indoor equipment is not
required to have a heat source
present, which is selectable with the
Indoor Equipment Stages setting. If
control of a PACKAGE UNIT is
desired and the PACKAGE UNIT has
a natural or propane heating source
installed, the FURNACE option
should be selected.
8
Scroll
Available
on APP