END USER SETTINGS - HUMIDITY
DEFINITION
DEPENDENCIES FUNCTION
The Humidity Screen is used to allow
the end user access to change or view
humidify and dehumidify set points on
the thermostat. The orange Hum
Setpoint Wheel is used to adjust the
humidify set point. The blue Dehum
Set point Wheel is used to adjust the
cool to dehumidify set point.
If the “ ” output is configured to
be used as a “O” or a “B” output
for a heat-pump or if the “ ”
output is configured to be used
as a “Y3” output for a 3-stage
cooling, the HUMIDIFY
functionality is not available in
the thermostat and the orange
Hum Setpoint Wheel will be
“greyed” and its functionality will
be disabled.
The “ ” output will be
enabled to energize a
24VAC signal to
humidifier equipment if
a humidity demand is
present and the
heating equipment is
actively heating.
20
Home*Bu?on
Available
on APP