114
2-2. Charging
■ Indicator operation
3 indicators are used to indicate the
following conditions.
Power indicator
Illuminates when electricity is flowing to
the CCID (Charging Circuit Interrupting
Device).
Charging indicator
Illuminates when charging is in prog-
ress.
Error warning indicator
Flashes when there is an electrical
leakage or when a malfunction occurs
in the CCID (Charging Circuit Interrupt-
ing Device).
■ When a malfunction occurs during charging
The indicators on the CCID (Charging Circuit Interrupting Device) use a
combination of different statuses (not illuminated, illuminated or flashing) to
inform the user of internal malfunctions.
When the error warning indicator is illuminated or flashing, temporarily remove the
plug from the socket and then reconnect it to check if the error indicator turns off.
If the error warning indicator turns off, charging is now possible.
If it does not turn off, perform the correction procedure in the following chart.
CCID (Charging Circuit Inter-
rupting Device) indicators
(Mode 2 AC charging cable)
B
C
Status
Power indica-
tor
Error warning
indicator
Cause/Correction procedure
Charging system
error
Not illuminated
Not illumi-
nated or illumi-
nated
An electrical leakage is
detected and charging is can-
celed, or there is a malfunction
in the AC charging cable.
Consult any authorized
Toyota retailer or Toyota
authorized repairer, or any
reliable repairer
Illuminated Flashes