© 2018 TP-Link
BSMI Notice
安全諮詢及注意事項
請使用原裝電源供應器或只能按照本產品注明的電源類型使用本產品。
清潔本產品之前請先拔掉電源線。請勿使用液體、噴霧清潔劑或濕布進行清潔。
注意防潮,請勿將水或其他液體潑灑到本產品上。
插槽與開口供通風使用,以確保本產品的操作可靠並防止過熱,請勿堵塞或覆蓋開口。
請勿將本產品置放於靠近熱源的地方。除非有正常的通風,否則不可放在密閉位置中。
請不要私自打開機殼,不要嘗試自行維修本產品,請由授權的專業人士進行此項工作。
此為甲類資訊技術設備,于居住環境中使用時,可能會造成射頻擾動,在此種情況下,使用者
會被要求採取某些適當的對策。
Explanation of the symbols on the product label
DC voltage
RECYCLING
This product bears the selective sorting symbol for Waste electrical and electronic equipment
(WEEE). This means that this product must be handled pursuant to European directive 2012/19/EU
in order to be recycled or dismantled to minimize its impact on the environment.
User has the choice to give his product to a competent recycling organization or to the retailer
when he buys a new electrical or electronic equipment.
Indoor use only
限用物質含有情況標示聲明書
限用物質及其化學符號
鉛
Pb
鎘
Cd
汞
Hg
六價鉻
CrVI
多溴聯苯
PBB
多溴二苯醚
PBDE
產品元件名稱
PCB
外殼
電源適配器
備考1. “超出0.1 wt%“及“超出0.01 wt%“系指限用物質之百分比含量超出百分
比含量基準值。
備考2. “ “系指該項限用物質之百分比含量未超出百分比含量基準值。
備考3. “ “系指該項限用物質為排除項目。
For TL-SG116E
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
For TL-SG105E/TL-SG108E
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communication.
FCC STATEMENT
For TL-SG116E
This is a class A product. In a domestic environment, this product may cause radio interference, in which
case the user may be required to take adequate measures.
For TL-SG105E/TL-SG108E
This is a class B product. In a domestic environment, this product may cause radio interference, in which
case the user may be required to take adequate measures.
TP-Link hereby declares that the device is in compliance with the essential requirements and other
relevant provisions of directives 2014/30/EU, 2014/35/EU, 2009/125/EC and 2011/65/EU.
The original EU declaration of conformity may be found at http://www.tp-link.com/en/ce
CE Mark Warning
Industry Canada Statement (For TL-SG105E/TL-SG108E)
CAN ICES-3 (B)/NMB-3(B)
Industry Canada Statement (For TL-SG116E)
CAN ICES-3 (A)/NMB-3(A)
Safety Information
Do not use any other chargers than those recommended.
Keep the device away from water, re, humidity or hot environments.
Do not use damaged charger or USB cable to charge the device.
Do not attempt to disassemble, repair, or modify the device.
Adapter shall be installed near the equipment and shall be easily accessible.
Use only power supplies which are provided by manufacturer and in the origin
packing of this product. If you have any questions, please don’t hesitate to contact us.
Frequently Asked Questions (FAQ)
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
0˚C to 40˚C (32˚F to 104˚F)
-40˚C to 70˚C (-40˚F to 158˚F)
10%RH to 90%RH non-condensing
5%RH to 90%RH non-condensing
Environmental and Physical Specications
Specications
The Power LED should be lit when the power system is working normally. If the
Power LED is not lit, please try the following:
A1:
Make sure the power adapter is connected to the switch with power source
properly.
A2:
Make sure the voltage of the power supply meets the requirements of the
input voltage of the switch.
A3:
Make sure the power source is ON.
Q1. Why is the Power LED not lit?
Q2. Why is the Link/Act LED not lit while a device is connected
to the corresponding port?
For technical support and other information, please visit
https://www.tp-link.com/support, or simply scan the QR code.
Please try the following:
A1:
Make sure that the cable connectors are rmly plugged into the switch and
the device.
A2
:
Make sure the connected device is turned on and works normally.
A3
:
The cable must be less than 100 meters long (328 feet).
Some models featured in this guide may be unavailable in your country or region.
For local sales information, visit https://www.tp-link.com.
Standard
Protocol
Interface
LED indicators
Transfer Method
IEEE802.3i, IEEE802.3u, IEEE802.3ab,
IEEE802.3x, IEEE802.1p, IEEE802.1q
CSMA/CD
Ethernet: 10Mbps (Half Duplex), 20Mbps (Full Duplex)
Fast Ethernet: 100Mbps (Half Duplex), 200Mbps (Full Duplex)
Gigabit Ethernet: 2000Mbps (Full Duplex)
10Base-T:
UTP category 3, 4, 5 cable (maximum 100m)
EIA/TIA-568 100
Ω
STP (maximum 100m)
100Base-TX:
UTP category 5, 5e cable (maximum 100m)
EIA/TIA-568 100
Ω
STP (maximum 100m)
1000Base-T:
UTP category 5e cable (maximum 100m)
EIA/TIA-568 100Ω STP (maximum 100m)
5/8/16 10/100/1000Mbps Auto-Negotiation RJ45 Ports
Power, 10/100M LED, 1000M LED
Store-and-Forward
Automatically learning, automatically aging
10Base-T: 14881pps/Port
100Base-TX: 148810pps/Port
1000Base-T: 1488095pps/Port
MAC Address Learning
Frame Forward Rate
General Specications
Data Transfer Rate
Network Media (Cable)
Wall Mountable
Distance Between
Mounting Holes
Yes
TL-SG105E: 52mm
TL-SG108E: 110mm
TL-SG116E: 200mm