You have purchased the latest in Handheld, Waterproof pH-mV-
Temperature instrumentation. We trust that your new Aqua-pH will give
you many years of reliable service.
The Aqua-pH is a breeze to operate. This manual has been designed to
help you get started, and also contains some handy application tips. If at
any stage you require assistance, please contact either your local TPS
representative or the TPS factory in Brisbane.
The manual is divided into the following sections:
1. Table of Contents
Each major section of the handbook is clearly listed. Sub-sections
have also been included to enable you to find the information you
need at a glance.
2. Introduction
The introduction has a diagram and explanation of the display and
controls of the Aqua-pH. It also contains a full listing of all of the
items that you should have received with your Aqua-pH. Please take
the time to read this section, as it explains some of items that are
mentioned in subsequent sections.
3. Main Section
The main section of the handbook provides complete details of the
Aqua-pH, including operating modes, calibration, troubleshooting,
specifications, and warranty terms.
4. Appendices
Appendices containing background information and application notes
are provided at the back of this manual.
TPS Pty Ltd
4 Jamberoo Street
Springwood, Brisbane,
Australia, 4127
Phone : (07) 32 900 400
International : 61 7 32 900 400
Fax : (07) 3808 4871
International : 61 7 3808 4871
Email : tps@tps.com.au
Web : www.tps.com.au
Model Aqua-pH
pH-mV-Temp. Meter
Version : 1.0
Date : 19/02/2002
Author : MS

Questions and Answers

  • C
    Carlos AndersonAug 19, 2025
    Why does my TPS Measuring Instruments display OFF and switch off?
    • S
      Sierra CooperSep 12, 2025
      If your TPS Measuring Instruments displays the word 'OFF' and then switches off, it means the battery voltage has dropped below 6.00 volts. To fix this, replace the battery.
  • W
    Wendy DiazAug 21, 2025
    What to do if my TPS Measuring Instruments will not turn on?
    • S
      samanthanelsonAug 21, 2025
      If your TPS Measuring Instruments won't turn on, the battery is likely exhausted. Replacing the battery should solve the problem.
  • C
    corteznicoleAug 23, 2025
    What does the flashing symbol mean on my TPS Measuring Instruments?
    • Y
      Yvette BrownAug 23, 2025
      If your TPS Measuring Instruments shows a flashing symbol, it indicates that the battery is below 7.50 volts. Replace the battery soon. The unit will automatically switch off when the battery level falls below 6.00 volts.
  • C
    Chad BeanAug 27, 2025
    Why are the readings inaccurate on my TPS Measuring Instruments even after calibration?
    • T
      thomasphillipsAug 28, 2025
      If your TPS Measuring Instruments shows inaccurate readings even after successful calibration, the reference junction is likely blocked. Clean the reference junction according to the instructions supplied with the sensor to resolve this.
  • J
    jasonfullerAug 29, 2025
    Why does the 2 point calibration fail on my TPS Measuring Instruments (slope less than 85.0%)?
    • S
      Susan GrahamAug 29, 2025
      If a 2-point calibration fails on your TPS Measuring Instruments because the slope is less than 85.0%, it could be due to several reasons: 1. Using an incorrect primary buffer. 2. The glass bulb is not clean. 3. The sensor is aged. 4. The connector is damp. 5. The buffers are inaccurate. To solve this: * Ensure you are using the buffers that the Aqua-pH has been set to automatically recognize. * Clean the glass bulb as per the instructions supplied with the sensor. * Attempt rejuvenation as per the instructions supplied with the sensor. Replace the sensor if rejuvenation is unsuccessful. * Dry the connector in a warm place. * Replace the buffers.
  • C
    cathybergAug 31, 2025
    Why does the 1 point calibration fail on my TPS Measuring Instruments (asymmetry greater than +/- 1.00 pH)?
    • A
      April JohnsonSep 1, 2025
      If a 1 Point calibration fails on your TPS Measuring Instruments (Asymmetry is greater than +/- 1.00 pH), it is likely due to a blocked reference junction or contaminated reference electrolyte. Clean the reference junction as per the instructions supplied with the sensor, flush with distilled water, and replace the electrolyte.
  • A
    April GraySep 3, 2025
    Why does my TPS Measuring Instruments display 7.00 for all solutions?
    • M
      Meghan MillerSep 3, 2025
      If your TPS Measuring Instruments displays 7.00 for all solutions, there is likely an electrical short in the connector. Check the connector and replace it if necessary. If the problem persists, replace the sensor.
  • H
    hjuarezSep 5, 2025
    Why does my TPS Measuring Instruments display 4-5 pH for all solutions?
    • C
      Christopher JacobsonSep 5, 2025
      If your TPS Measuring Instruments displays 4-5 pH for all solutions, the glass bulb or internal stem is likely cracked. The solution is to replace the sensor.
  • K
    Karen HallSep 7, 2025
    What to do if my TPS Measuring Instruments fails to calibrate, even with a new sensor?
    • R
      ramosvirginiaSep 7, 2025
      If your TPS Measuring Instruments fails to calibrate, even with a new sensor, the calibration settings are likely outside of allowable limits due to a previous failed calibration. Initialise the unit.
  • J
    John PonceSep 9, 2025
    Why does my TPS Measuring Instruments display “OVRoC” when the sensor is plugged in?
    • D
      Dr. Sandra WilliamsSep 9, 2025
      If your TPS Measuring Instruments displays “OVRoC” when the sensor is plugged in, it indicates either a faulty sensor or a faulty instrument. Try fitting a new sensor, part number 121247. If the issue persists, return the instrument to the factory for repair.

Summary

Introduction

Aqua-pH Display and Controls

Details the display and control buttons of the Aqua-pH instrument.

Unpacking Information

Lists the accessories included with the Aqua-pH and optional items.

Specifications

Provides technical specifications for the Aqua-pH meter, including ranges, resolution, and accuracy.

Operating Modes

pH Calibration

Calibration Steps

Step-by-step instructions for calibrating the pH of the Aqua-pH meter.

pH Calibration Notes

Provides important notes and recommendations for performing pH calibrations.

pH Calibration Messages

Explains common messages displayed during pH calibration and their meaning.

Millivolt Calibration

Temperature Calibration

Temperature Calibration Steps

Detailed procedure for calibrating the temperature sensor of the Aqua-pH.

Temperature Calibration Notes

Important considerations and notes for temperature calibration.

Temperature Calibration Messages

Interprets messages shown during temperature calibration.

Manual Temperature Setting

Procedure for manually setting the temperature compensation.

Selecting Buffers for Auto Buffer Recognition

Battery Saver Function

Initialising the Aqua-pH

Troubleshooting

General Error Messages

Lists common error messages, their causes, and remedies.

pH and mV Troubleshooting

Addresses issues related to pH and mV calibration and readings.

Temperature Troubleshooting

Diagnoses and resolves problems with temperature readings and calibration.

Appendices

pH Sensor Fundamentals

Explains the basic principles and components of a pH sensor.

Checking the Reference Junction

Procedure to test and troubleshoot the pH sensor's reference junction.

Determining Instrument or Sensor Faults

Tests to help identify if the Aqua-pH meter or its sensor is faulty.

Instrument Software Version Number

Information on how to find and report the Aqua-pH firmware version and serial number.

Warranty

TPS Aqua-pH Specifications

General IconGeneral
Resolution0.01 pH
Accuracy±0.01 pH
ATCYes
pH Range0 to 14 pH
Temperature CompensationAutomatic
DisplayLCD
Power Supply4 x AAA batteries