Congratulations !
You have purchased the latest in Handheld, Waterproof pH-mV-
Temperature instrumentation. We trust that your new Aqua-pH will give
you many years of reliable service.
The Aqua-pH is a breeze to operate. This manual has been designed to
help you get started, and also contains some handy application tips. If at
any stage you require assistance, please contact either your local TPS
representative or the TPS factory in Brisbane.
The manual is divided into the following sections:
1. Table of Contents
Each major section of the handbook is clearly listed. Sub-sections
have also been included to enable you to find the information you
need at a glance.
2. Introduction
The introduction has a diagram and explanation of the display and
controls of the Aqua-pH. It also contains a full listing of all of the
items that you should have received with your Aqua-pH. Please take
the time to read this section, as it explains some of items that are
mentioned in subsequent sections.
3. Main Section
The main section of the handbook provides complete details of the
Aqua-pH, including operating modes, calibration, troubleshooting,
specifications, and warranty terms.
4. Appendices
Appendices containing background information and application notes
are provided at the back of this manual.
TPS Pty Ltd
4 Jamberoo Street
Springwood, Brisbane,
Australia, 4127
Phone : (07) 32 900 400
International : 61 7 32 900 400
Fax : (07) 3808 4871
International : 61 7 3808 4871
Email : tps@tps.com.au
Web : www.tps.com.au
Model Aqua-pH
pH-mV-Temp. Meter
Version : 1.0
Date : 19/02/2002
Author : MS

Questions and Answers

  • K
    Kyle HarrisSep 12, 2025
    Why is the temperature inaccurate on my TPS Measuring Instruments and cannot be calibrated?
    • A
      angela57Sep 12, 2025
      If the temperature reading is inaccurate on your TPS Measuring Instruments and cannot be calibrated, it could be due to a faulty connector, sensor, or instrument. Check the connector and replace it if necessary. If the problem persists, fit a new sensor (part number 121247). If the issue still continues, return the instrument to the factory for repair.
  • H
    hhicksSep 13, 2025
    What does 'Memory Failed Calib. Lost Memory Reset ! You MUST Re-Cal.' mean on my TPS Measuring Instruments?
    • B
      Brandon CalderonSep 13, 2025
      If your TPS Measuring Instruments displays 'Memory Failed Calib. Lost Memory Reset ! You MUST Re-Cal.', it means that user calibration settings have been lost or corrupted. Re-calibrate the instrument. A 2 point calibration is required for pH and a 1 point calibration for temperature.
  • M
    Michelle FergusonSep 16, 2025
    What does 'Factory Cal. Fail See Handbook' mean on my TPS Measuring Instruments?
    • J
      James NguyenSep 16, 2025
      If your TPS Measuring Instruments displays 'Factory Cal. Fail See Handbook', it means that the EEPROM chip, which contains the factory calibration information, has failed. The unit must be returned to TPS for service.
  • J
    Julia MunozNov 24, 2025
    Why are the readings unstable on my TPS Measuring Instruments?
    • D
      David WillisNov 24, 2025
      Unstable readings on your TPS Measuring Instruments can be due to several reasons: * A blocked reference junction. * A dirty glass bulb. * A bubble in the glass bulb. * A faulty connection to the meter. * The reference junction not being immersed properly. * KCl crystals around the reference junction inside the electrolyte chamber. To resolve this: * Clean the reference junction as per instructions supplied with the sensor. * Clean the glass bulb as per instructions supplied with the sensor. * Flick the sensor to remove any bubble. * Check the connectors and replace if necessary. * Ensure both the bulb and the reference junction are fully immersed. * Rinse the electrolyte chamber with warm distilled water until the crystals are dissolved, then replace the electr...

Summary

Introduction

Aqua-pH Display and Controls

Details the display and control buttons of the Aqua-pH instrument.

Unpacking Information

Lists the accessories included with the Aqua-pH and optional items.

Specifications

Provides technical specifications for the Aqua-pH meter, including ranges, resolution, and accuracy.

Operating Modes

pH Calibration

Calibration Steps

Step-by-step instructions for calibrating the pH of the Aqua-pH meter.

pH Calibration Notes

Provides important notes and recommendations for performing pH calibrations.

pH Calibration Messages

Explains common messages displayed during pH calibration and their meaning.

Millivolt Calibration

Temperature Calibration

Temperature Calibration Steps

Detailed procedure for calibrating the temperature sensor of the Aqua-pH.

Temperature Calibration Notes

Important considerations and notes for temperature calibration.

Temperature Calibration Messages

Interprets messages shown during temperature calibration.

Manual Temperature Setting

Procedure for manually setting the temperature compensation.

Selecting Buffers for Auto Buffer Recognition

Battery Saver Function

Initialising the Aqua-pH

Troubleshooting

General Error Messages

Lists common error messages, their causes, and remedies.

pH and mV Troubleshooting

Addresses issues related to pH and mV calibration and readings.

Temperature Troubleshooting

Diagnoses and resolves problems with temperature readings and calibration.

Appendices

pH Sensor Fundamentals

Explains the basic principles and components of a pH sensor.

Checking the Reference Junction

Procedure to test and troubleshoot the pH sensor's reference junction.

Determining Instrument or Sensor Faults

Tests to help identify if the Aqua-pH meter or its sensor is faulty.

Instrument Software Version Number

Information on how to find and report the Aqua-pH firmware version and serial number.

Warranty

TPS Aqua-pH Specifications

General IconGeneral
Resolution0.01 pH
Accuracy±0.01 pH
ATCYes
pH Range0 to 14 pH
Temperature CompensationAutomatic
DisplayLCD
Power Supply4 x AAA batteries